Performance and Investigation Analysis of Extended Source Vertical Tunnel Field Effect Transistor‐Based High‐Sensitivity pH Sensor

This article presents an innovative extended source structure for vertical tunnel field effect transistor as a pH sensor for detecting bio‐electrolyte. In this structure, the source has been extended inside the channel to improve the sensitivity. The optimal extended source inside the channel is S h = 30 nm, which shows the higher drain current and drain current sensitivity. Current sensitivity has also been examined for the proposed structure with variations in pH value. An electrolyte model and site binding model have also been developed for surface potential in order to better understand device physics as a pH sensor, as pH changes directly impact surface charge density, thus detecting small changes. In addition, the pH sensor's response to variations in extended sources has been investigated. Additionally, the proposed pH sensor has a voltage sensitivity of about 100 mV pH −1 , exceeding Nernst's limit.

Authors

Institutions

Publication Details

Journal
physica status solidi (a)
Published
2025-03-09
DOI
https://doi.org/10.1002/pssa.202400967
Citations
1
Primary Topic
Analytical Chemistry and Sensors
Type
article
Field-Weighted Citation Impact
0.74
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Performance and Investigation Analysis of Extended Source Vertical Tunnel Field Effect Transistor‐Based High‐Sensitivity pH Sensor

Ankur Beohar, Srinivas Burra
1 citations
physica status solidi (a)
Analytical Chemistry and Sensors
0.74
article

Performance and Investigation Analysis of Extended Source Vertical Tunnel Field Effect Transistor‐Based High‐Sensitivity pH Sensor

Ankur Beohar, Srinivas Burra
article en
1 citations

Abstract

This article presents an innovative extended source structure for vertical tunnel field effect transistor as a pH sensor for detecting bio‐electrolyte. In this structure, the source has been extended inside the channel to improve the sensitivity. The optimal extended source inside the channel is S h = 30 nm, which shows the higher drain current and drain current sensitivity. Current sensitivity has also been examined for the proposed structure with variations in pH value. An electrolyte model and site binding model have also been developed for surface potential in order to better understand device physics as a pH sensor, as pH changes directly impact surface charge density, thus detecting small changes. In addition, the pH sensor's response to variations in extended sources has been investigated. Additionally, the proposed pH sensor has a voltage sensitivity of about 100 mV pH −1 , exceeding Nernst's limit.

physica status solidi (a)Vol. 223(2)
Barkatullah University (IN)
Openalex Percentile: Top 37%
Analytical Chemistry and Sensors
0.74
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines