Soft Flexible Skin Conformable Nanocomposites as a Platform for Electroceutical and Orthopedic Applications

Designing biomimetic substrates and electrodes for bioelectronic devices with the necessary mechanical, electrical, and biological properties is critical considering the potential mismatch between soft tissue and rigid electronics, where incompatibility leads to decreased device performance, delamination, inflammation, and discomfort. There is an unmet engineering and clinical need for epidermal bioelectronics that are bioinert, can emulate host tissue mechanical properties, demonstrate low bulk resistivity, and are flexible and scalable. To address this shortcoming, this work describes innovations pertaining to the development of a hydrophilic, biocompatible nanocomposite comprised of carbon black (CB), polyvinyl alcohol (PVA), and glycerol for neuro-muscular and rehabilitative applications. We find that this materials platform (herein referred to as CB-AFTIDerm), comprised of 3 wt% PVA and 5 wt% glycerol, demonstrated superior biocompatibility (cytotoxic grade of 0), high flexibility (maximum of 140% stretchability and as low as 1% ∆R/R<sub>o</sub> at 3.5-cm bending diameter), low electrical resistivity (as low as 0.6 Ω.cm), and electrical stability over a long-term duration (at 235 Ω in the lateral direction and between 300 Ω and 400 Ω in the transverse direction for a 24 h period). We find that the optimal CB concentration for our material platform is at 50% CB. We present examples for use in electroceutical therapy of chronic wounds and in orthopedic rehabilitation for monitoring joint angles. Achieving such results from a material, mechanics, biological, and electrical perspective facilitates the translational potential of this materials platform for the digital health and wearable technologies community to improve patient outcomes.

Authors

Institutions

Publication Details

Journal
Journal of Biomedical Materials Research Part B Applied Biomaterials
Published
2025-03-01
DOI
https://doi.org/10.1002/jbm.b.35559
Citations
1
Primary Topic
Advanced Sensor and Energy Harvesting Materials
Type
article
Field-Weighted Citation Impact
0.67

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Soft Flexible Skin Conformable Nanocomposites as a Platform for Electroceutical and Orthopedic Applications

Nicholas D. Bianco, Aziz N. Radwan, Dhruv R. Seshadri, Kath M. Bogie et al.
1 citations
Journal of Biomedical Materials Research Part B Applied Biomaterials
Advanced Sensor and Energy Harvesting Materials
0.67
article

Soft Flexible Skin Conformable Nanocomposites as a Platform for Electroceutical and Orthopedic Applications

Nicholas D. Bianco, Aziz N. Radwan, Dhruv R. Seshadri, Kath M. Bogie, Joseph Lerchbacker, Christian A. Zorman, Audrey M. Zorman
article en
1 citations

Abstract

Designing biomimetic substrates and electrodes for bioelectronic devices with the necessary mechanical, electrical, and biological properties is critical considering the potential mismatch between soft tissue and rigid electronics, where incompatibility leads to decreased device performance, delamination, inflammation, and discomfort. There is an unmet engineering and clinical need for epidermal bioelectronics that are bioinert, can emulate host tissue mechanical properties, demonstrate low bulk resistivity, and are flexible and scalable. To address this shortcoming, this work describes innovations pertaining to the development of a hydrophilic, biocompatible nanocomposite comprised of carbon black (CB), polyvinyl alcohol (PVA), and glycerol for neuro-muscular and rehabilitative applications. We find that this materials platform (herein referred to as CB-AFTIDerm), comprised of 3 wt% PVA and 5 wt% glycerol, demonstrated superior biocompatibility (cytotoxic grade of 0), high flexibility (maximum of 140% stretchability and as low as 1% ∆R/R<sub>o</sub> at 3.5-cm bending diameter), low electrical resistivity (as low as 0.6 Ω.cm), and electrical stability over a long-term duration (at 235 Ω in the lateral direction and between 300 Ω and 400 Ω in the transverse direction for a 24 h period). We find that the optimal CB concentration for our material platform is at 50% CB. We present examples for use in electroceutical therapy of chronic wounds and in orthopedic rehabilitation for monitoring joint angles. Achieving such results from a material, mechanics, biological, and electrical perspective facilitates the translational potential of this materials platform for the digital health and wearable technologies community to improve patient outcomes.

Journal of Biomedical Materials Research Part B Applied BiomaterialsVol. 113(3)
Lehigh University (US), Louis Stokes Cleveland VA Medical Center (US), The Ohio State University (US), Case Western Reserve University (US)
U.S. Department of Veterans Affairs
Openalex Percentile: Top 34%
Advanced Sensor and Energy Harvesting Materials
0.67
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.