Seismic Performance Assessment of Insulated and Conventional Cross‐Arms Transmission Tower‐Line System

ABSTRACT The electrical safety gap between conductors and trees can be increased by substituting insulated cross‐arms for conventional cross‐arms, which is increasingly used in the rehabilitation of existing transmission lines. To study the seismic performance of insulated cross‐arm transmission tower structures, this paper establishes transmission single tower and tower‐line system finite model and performs mechanical analysis of the cross‐arm and nonlinear dynamic response analysis of the structure under 150 seismic conditions of different parameters. The relationship between seismic strength and structural response is fitted, and the seismic performance of the transmission tower structure is evaluated. The results show that by substituting insulated cross‐arms for conventional cross‐arms, the maximum displacement of the vertex of the single tower and tower‐line system model can be reduced by 20.43% and 111.83%, respectively; when PGA = 0.2 g, the probability of collapse of a single tower structure and a tower‐line system can be reduced by 0.49% and 11.66%, respectively. The research in this paper provides a useful reference for the further application of insulating cross‐arms.

Authors

Institutions

Publication Details

Journal
The Structural Design of Tall and Special Buildings
Published
2025-03-01
DOI
https://doi.org/10.1002/tal.70011
Primary Topic
Seismic Performance and Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Seismic Performance Assessment of Insulated and Conventional Cross‐Arms Transmission Tower‐Line System

Yanzhong Ju, Dehong Wang, Xinyuan Zhang
The Structural Design of Tall and Special Buildings
Seismic Performance and Analysis
article

Seismic Performance Assessment of Insulated and Conventional Cross‐Arms Transmission Tower‐Line System

Yanzhong Ju, Dehong Wang, Xinyuan Zhang
article en

Abstract

ABSTRACT The electrical safety gap between conductors and trees can be increased by substituting insulated cross‐arms for conventional cross‐arms, which is increasingly used in the rehabilitation of existing transmission lines. To study the seismic performance of insulated cross‐arm transmission tower structures, this paper establishes transmission single tower and tower‐line system finite model and performs mechanical analysis of the cross‐arm and nonlinear dynamic response analysis of the structure under 150 seismic conditions of different parameters. The relationship between seismic strength and structural response is fitted, and the seismic performance of the transmission tower structure is evaluated. The results show that by substituting insulated cross‐arms for conventional cross‐arms, the maximum displacement of the vertex of the single tower and tower‐line system model can be reduced by 20.43% and 111.83%, respectively; when PGA = 0.2 g, the probability of collapse of a single tower structure and a tower‐line system can be reduced by 0.49% and 11.66%, respectively. The research in this paper provides a useful reference for the further application of insulating cross‐arms.

The Structural Design of Tall and Special BuildingsVol. 34(4)
Northeast Electric Power University (CN)
Openalex Percentile: Top 95%
Seismic Performance and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.