Screening Procedures for Self‐Reactive Substances, Differential Scanning Calorimetry‐Onset and Heat‐Flux Criteria

Abstract We present a new screening procedure for the determination of the thermal stability of potential candidates for the class of self‐reactive substances. For the classification of self‐reactive substances, elaborate testing is necessary to determine the applicable type, according to the regulations. Annex 6 of the UN Manual of Tests and Criteria permits that the classification procedure for self‐reactive substances may be omitted, if the estimated self accelerating decomposition temperature (SADT) is greater than 75 °C for a 50 kg package using an appropriate calorimetric technique, but no technique is described. Based on stationary theories of thermal explosion, we developed a screening approach using differential scanning calorimetry (DSC) onset and heat‐flux criteria, respectively, at relevant temperatures. The proposed approach is validated with experimental data.

Authors

Institutions

Publication Details

Journal
Chemical Engineering & Technology
Published
2025-03-01
DOI
https://doi.org/10.1002/ceat.12006
Primary Topic
Thermal and Kinetic Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Screening Procedures for Self‐Reactive Substances, Differential Scanning Calorimetry‐Onset and Heat‐Flux Criteria

Marcus Malow, Markus Gödde, J. C. Clemens
Chemical Engineering & Technology
Thermal and Kinetic Analysis
article

Screening Procedures for Self‐Reactive Substances, Differential Scanning Calorimetry‐Onset and Heat‐Flux Criteria

Marcus Malow, Markus Gödde, J. C. Clemens
article en

Abstract

Abstract We present a new screening procedure for the determination of the thermal stability of potential candidates for the class of self‐reactive substances. For the classification of self‐reactive substances, elaborate testing is necessary to determine the applicable type, according to the regulations. Annex 6 of the UN Manual of Tests and Criteria permits that the classification procedure for self‐reactive substances may be omitted, if the estimated self accelerating decomposition temperature (SADT) is greater than 75 °C for a 50 kg package using an appropriate calorimetric technique, but no technique is described. Based on stationary theories of thermal explosion, we developed a screening approach using differential scanning calorimetry (DSC) onset and heat‐flux criteria, respectively, at relevant temperatures. The proposed approach is validated with experimental data.

Chemical Engineering & TechnologyVol. 48(3)
Federal Institute For Materials Research and Testing (DE), Bayer (Germany) (DE), Robert Bosch (Germany) (DE)
Openalex Percentile: Top 97%
Thermal and Kinetic Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.