Analysis of DC Bus Bar Inductance on Performance of 2-level Inverter

In a 2-level inverter, the DC bus bar links the power module to the DC-link capacitors. During hard switching of the power semiconductor, the stray inductance of the bus bar generates voltage overshoots across the switch and the DC bus. Existing literature primarily investigates the impact of these overshoots on the inverter's electromagnetic emissions. This paper focuses on assessing the effect of voltage overshoots on inverter switching losses through a combination of Double Pulse Test (DPT) simulations, drive cycle simulations, and experimental voltage overshoot analysis. Two bus bar prototypes with a 26% difference in stray inductance were developed for a 2-level inverter. The switching losses of the semiconductor were evaluated over drive cycles, revealing a 0.94% increase in energy losses due to the higher bus bar inductance. In line with that, switch-level DPT results indicated an increase of 1.14%. This suggests that analyzing inverter switching losses through drive cycle simulations is important as voltage spike measurement which shows a considerable amount of switching energy loss. Further, the voltage overshoot analysis reveals a 12% reduction in voltage stress on the switch attributable to stray inductance both in simulation and experiment.

Authors

Institutions

Publication Details

Published
2024-11-03
DOI
https://doi.org/10.1109/iecon55916.2024.10905149
Primary Topic
Multilevel Inverters and Converters
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Analysis of DC Bus Bar Inductance on Performance of 2-level Inverter

Andre Uhlemann, Artem Rodionov, Yujing Liu, Nimananda Sharma et al.
Multilevel Inverters and Converters
article

Analysis of DC Bus Bar Inductance on Performance of 2-level Inverter

Andre Uhlemann, Artem Rodionov, Yujing Liu, Nimananda Sharma, Hari Sankar Natesan Sugumar, Pablo Paz Sagues
article en

Abstract

In a 2-level inverter, the DC bus bar links the power module to the DC-link capacitors. During hard switching of the power semiconductor, the stray inductance of the bus bar generates voltage overshoots across the switch and the DC bus. Existing literature primarily investigates the impact of these overshoots on the inverter's electromagnetic emissions. This paper focuses on assessing the effect of voltage overshoots on inverter switching losses through a combination of Double Pulse Test (DPT) simulations, drive cycle simulations, and experimental voltage overshoot analysis. Two bus bar prototypes with a 26% difference in stray inductance were developed for a 2-level inverter. The switching losses of the semiconductor were evaluated over drive cycles, revealing a 0.94% increase in energy losses due to the higher bus bar inductance. In line with that, switch-level DPT results indicated an increase of 1.14%. This suggests that analyzing inverter switching losses through drive cycle simulations is important as voltage spike measurement which shows a considerable amount of switching energy loss. Further, the voltage overshoot analysis reveals a 12% reduction in voltage stress on the switch attributable to stray inductance both in simulation and experiment.

Infineon Technologies (Germany) (DE), Chalmers University of Technology (SE)
Affordable and clean energy
Openalex Percentile: Top 74%
Multilevel Inverters and Converters
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.