Effects of Robotic Gait Training Combined with a 3D-Printed Custom Orthosis for Hemiparetic Stroke Patient

Purpose This study aimed to investigate the effects of robotic gait training combined with a 3D-printed custom orthosis on the 10-Meter Walking Test (10MWT), Timed Up & Go Test (TUG), and Functional Gait Assessment (FGA) in a hemiparetic stroke patient. Methods A single stroke patient participated in this study, which employed a Single-Subject Research Design with an A-B-A’ structure. The participant underwent robotic gait training and engaged in independent walking training indoors for 30 minutes while wearing the 3D-printed custom orthosis. The total duration of the study, including the intervention phase, was 15 days. Results The average values for the 10MWT were as follows: Baseline, 14.92 ± 0.41 sec; Intervention, 12.00 ± 0.43 sec; and Retention, 11.55 ± 0.43 sec. The average TUG test times were Baseline, 31.70 ± 0.13 sec; Intervention, 25.52 ± 2.52 sec; and Retention, 23.70 ± 0.38 sec. In the FGA, the total score increased by 1 point, reaching a final score of 6. Conclusion These findings suggest that robotic gait training combined with a 3D-printed custom orthosis may have a greater positive impact on 10MWT, TUG, and FGA outcomes in stroke patients compared to lower-limb robotic therapy alone.

Authors

Publication Details

Journal
Journal of Clinical Movement Science in Human
Published
2025-03-07
DOI
https://doi.org/10.17817/jcmsh.2025.29.1.8
Primary Topic
Stroke Rehabilitation and Recovery
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Effects of Robotic Gait Training Combined with a 3D-Printed Custom Orthosis for Hemiparetic Stroke Patient

Byung-Il Yang
Journal of Clinical Movement Science in Human
Stroke Rehabilitation and Recovery
article

Effects of Robotic Gait Training Combined with a 3D-Printed Custom Orthosis for Hemiparetic Stroke Patient

Byung-Il Yang
article en

Abstract

Purpose This study aimed to investigate the effects of robotic gait training combined with a 3D-printed custom orthosis on the 10-Meter Walking Test (10MWT), Timed Up & Go Test (TUG), and Functional Gait Assessment (FGA) in a hemiparetic stroke patient. Methods A single stroke patient participated in this study, which employed a Single-Subject Research Design with an A-B-A’ structure. The participant underwent robotic gait training and engaged in independent walking training indoors for 30 minutes while wearing the 3D-printed custom orthosis. The total duration of the study, including the intervention phase, was 15 days. Results The average values for the 10MWT were as follows: Baseline, 14.92 ± 0.41 sec; Intervention, 12.00 ± 0.43 sec; and Retention, 11.55 ± 0.43 sec. The average TUG test times were Baseline, 31.70 ± 0.13 sec; Intervention, 25.52 ± 2.52 sec; and Retention, 23.70 ± 0.38 sec. In the FGA, the total score increased by 1 point, reaching a final score of 6. Conclusion These findings suggest that robotic gait training combined with a 3D-printed custom orthosis may have a greater positive impact on 10MWT, TUG, and FGA outcomes in stroke patients compared to lower-limb robotic therapy alone.

Journal of Clinical Movement Science in HumanVol. 29(1)
Openalex Percentile: Top 94%
Stroke Rehabilitation and Recovery
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.