The indoor air quality and the occurrence of sick building syndrome among employees in the central surgery building of hospital X, Bandung

Background: The prevalence of SBS (Sick Building Syndrome) among employees working in hospitals ranges from 21% to 80%, which is higher compared to other places. SBS has become an issue due to poor indoor air quality, including at Hospital X in Bandung. Purpose: To analyze the relationship between indoor air quality and the incidence of Sick Building Syndrome among workers in the Central Surgery Building of Hospital X, Bandung. Method: An analytical observational study with a cross-sectional design. The study population consisted of 105 permanent employees of the Central Surgery Unit. A sample of 91 workers was selected using random sampling. Inclusion criteria were permanent employment and working >7 hours a day, while exclusion criteria included employees on leave, sick, or unavailable. Data were collected through observation using instruments such as a thermohygrometer to measure temperature and humidity, a lux meter for lighting, a sound level meter for noise, and an anemometer for ACH (Air Changes per Hour), following the standards of the Ministry of Health Regulation No. 2 of 2023. Additionally, interviews were conducted using a questionnaire containing questions about SBS symptoms to gather data on the occurrence of SBS. Data analysis used Chi-square and logistic regression at a 95% confidence level and an alpha of 0.05. Results: The study results indicated that the indoor air quality did not meet the required standards: temperature (77.3%), humidity (86.4%), lighting (63.6%), noise (0%), bacterial count (63.3%), fungal count (77.3%), and ACH (63.3%). There was a significant relationship between temperature, humidity, and ACH with the occurrence of SBS (p=0.001; p=0.003; p=0.031). However, there was no significant relationship between lighting, bacterial count, and fungal count with SBS (p=0.181; p=0.264, p=0.066). Conclusion: Temperature, humidity, and ACH are variables that are associated with the occurrence of SBS.

Authors

Institutions

Publication Details

Journal
Malahayati International Journal of Nursing and Health Science
Published
2025-03-01
DOI
https://doi.org/10.33024/minh.v7i12.663
Primary Topic
Air Quality and Health Impacts
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The indoor air quality and the occurrence of sick building syndrome among employees in the central surgery building of hospital X, Bandung

Hefnita Hefnita, Suhartono Suhartono, Budiyono Budiyono
Malahayati International Journal of Nursing and Health Science
Air Quality and Health Impacts
article

The indoor air quality and the occurrence of sick building syndrome among employees in the central surgery building of hospital X, Bandung

Hefnita Hefnita, Suhartono Suhartono, Budiyono Budiyono
article en

Abstract

Background: The prevalence of SBS (Sick Building Syndrome) among employees working in hospitals ranges from 21% to 80%, which is higher compared to other places. SBS has become an issue due to poor indoor air quality, including at Hospital X in Bandung. Purpose: To analyze the relationship between indoor air quality and the incidence of Sick Building Syndrome among workers in the Central Surgery Building of Hospital X, Bandung. Method: An analytical observational study with a cross-sectional design. The study population consisted of 105 permanent employees of the Central Surgery Unit. A sample of 91 workers was selected using random sampling. Inclusion criteria were permanent employment and working >7 hours a day, while exclusion criteria included employees on leave, sick, or unavailable. Data were collected through observation using instruments such as a thermohygrometer to measure temperature and humidity, a lux meter for lighting, a sound level meter for noise, and an anemometer for ACH (Air Changes per Hour), following the standards of the Ministry of Health Regulation No. 2 of 2023. Additionally, interviews were conducted using a questionnaire containing questions about SBS symptoms to gather data on the occurrence of SBS. Data analysis used Chi-square and logistic regression at a 95% confidence level and an alpha of 0.05. Results: The study results indicated that the indoor air quality did not meet the required standards: temperature (77.3%), humidity (86.4%), lighting (63.6%), noise (0%), bacterial count (63.3%), fungal count (77.3%), and ACH (63.3%). There was a significant relationship between temperature, humidity, and ACH with the occurrence of SBS (p=0.001; p=0.003; p=0.031). However, there was no significant relationship between lighting, bacterial count, and fungal count with SBS (p=0.181; p=0.264, p=0.066). Conclusion: Temperature, humidity, and ACH are variables that are associated with the occurrence of SBS.

Malahayati International Journal of Nursing and Health ScienceVol. 7(12)
Diponegoro University (ID)
Openalex Percentile: Top 95%
Air Quality and Health Impacts
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.