Resilience assessment of coordinated energy storage assets in low-carbon grids

The resilience of power systems to extreme events is under increasing threat due to the high penetration of renewable generation. This paper examines the strategic use of energy storage to ensure the resilience of a low-carbon grid with different penetrations of renewable generation. Through real-time simulations of the loss of transmission lines or generators, coordinated energy storage assets are used to reduce frequency deviations and maintain load supplies. Based on simulations of the modified IEEE nine-bus system in RTDS, the influence of storage location and capacity are analysed. Results indicate that increasing renewable power penetration from 30% to 70% causes the lowest frequency after a disturbance to drop from 48.17 Hz to 47.48 Hz (based on a 50-Hz grid) when the two most sensitive transmission lines are lost, and the load shedding ratio increases from 0.50 to 0.60. Installing storage at a load-connected bus is seen to be most effective in this example network to improve resilience. For example, increasing storage capacity to 42.5% of system capacity reduces the load shedding ratio from 0.5 to 0.0 when two lines are lost with up to 60% renewable penetration.

Authors

Institutions

Publication Details

Journal
IET conference proceedings.
Published
2025-03-01
DOI
https://doi.org/10.1049/icp.2024.4589
Primary Topic
Optimal Power Flow Distribution
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Resilience assessment of coordinated energy storage assets in low-carbon grids

Andrew J. Hutchinson, Haris Patsios, Daniel T. Gladwin, Hui Yan et al.
2 links
IET conference proceedings.
Optimal Power Flow Distribution
article

Resilience assessment of coordinated energy storage assets in low-carbon grids

Andrew J. Hutchinson, Haris Patsios, Daniel T. Gladwin, Hui Yan, Jonathan Radcliffe, Thomas S. Bryden, Tanuj Rawat, Andrew J. Forsyth, Arman Alahyari, Dan Rogers
article en

Abstract

The resilience of power systems to extreme events is under increasing threat due to the high penetration of renewable generation. This paper examines the strategic use of energy storage to ensure the resilience of a low-carbon grid with different penetrations of renewable generation. Through real-time simulations of the loss of transmission lines or generators, coordinated energy storage assets are used to reduce frequency deviations and maintain load supplies. Based on simulations of the modified IEEE nine-bus system in RTDS, the influence of storage location and capacity are analysed. Results indicate that increasing renewable power penetration from 30% to 70% causes the lowest frequency after a disturbance to drop from 48.17 Hz to 47.48 Hz (based on a 50-Hz grid) when the two most sensitive transmission lines are lost, and the load shedding ratio increases from 0.50 to 0.60. Installing storage at a load-connected bus is seen to be most effective in this example network to improve resilience. For example, increasing storage capacity to 42.5% of system capacity reduces the load shedding ratio from 0.5 to 0.0 when two lines are lost with up to 60% renewable penetration.

IET conference proceedings.Vol. 2024(32)
University of Manchester (GB), University of Oxford (GB), University of Birmingham (GB), Newcastle University (GB), University of Sheffield (GB)
Engineering and Physical Sciences Research Council
Affordable and clean energy
Openalex Percentile: Top 97%
Optimal Power Flow Distribution
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.