Experimental and reliability assessment of fire resistance of glue laminated timber beams

Glue-laminated timber (GLT) is an engineered wood product widely used in mass timber construction for its strong structural and fire-resistant properties. However, the fire performance of GLT varies significantly due to the natural and uncertain phenomena (moisture, exposure time, isotropic, homogenous properties, etc.) of fire and timber. This makes it difficult to predict the fire behaviour of the GLT structural elements. To ensure building safety, it is crucial to assess GLT's fire behaviour and post-fire structural integrity during the design stages. This study conducted the experimental tests of GLT beams (280 mm × 560 mm) without loading (1.4 m) and under a four-point bending load (5.4 m). Tests identified thermal behaviour and charring rates of GLT beam. Then, the residual stiffness of the GLT beam was calculated, and the charring rates of the beams were compared with Australian and European standards. Reliability analysis was conducted for beams for a fire exposure of 120 min, considering the charring rates observed through the analysis and simulating the fire insulations. Results show that the charring rate of GLT made with spruce pine timber varied between 0.43 and 0.81 mm/min, with a mean rate of 0.7 mm/min, aligning with both Australian and European standards. However, considering timber density and moisture content, the charring rates in Australian standards were conservative. The study also found that structural capacity significantly degrades under fire, with a 22 % reduction in flexural stiffness after 120 min of exposure. Additionally, GLT beams can safely function for 30 min under 75 % of their design moment capacity and for 60 min under 50 % capacity.

Authors

Institutions

Publication Details

Journal
Resilient Cities and Structures
Published
2025-03-01
DOI
https://doi.org/10.1016/j.rcns.2025.02.004
Citations
4
Primary Topic
Wood Treatment and Properties
Type
article
Field-Weighted Citation Impact
4.03
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Experimental and reliability assessment of fire resistance of glue laminated timber beams

Solomon Tesfamariam, Pathmanathan Rajeev, Thusiyanthan Ponnampalam, Satheeskumar Navaratnam et al.
4 citations
Resilient Cities and Structures
Wood Treatment and Properties
4.03
article

Experimental and reliability assessment of fire resistance of glue laminated timber beams

Solomon Tesfamariam, Pathmanathan Rajeev, Thusiyanthan Ponnampalam, Satheeskumar Navaratnam, Thisari Munmulla
article en
4 citations

Abstract

Glue-laminated timber (GLT) is an engineered wood product widely used in mass timber construction for its strong structural and fire-resistant properties. However, the fire performance of GLT varies significantly due to the natural and uncertain phenomena (moisture, exposure time, isotropic, homogenous properties, etc.) of fire and timber. This makes it difficult to predict the fire behaviour of the GLT structural elements. To ensure building safety, it is crucial to assess GLT's fire behaviour and post-fire structural integrity during the design stages. This study conducted the experimental tests of GLT beams (280 mm × 560 mm) without loading (1.4 m) and under a four-point bending load (5.4 m). Tests identified thermal behaviour and charring rates of GLT beam. Then, the residual stiffness of the GLT beam was calculated, and the charring rates of the beams were compared with Australian and European standards. Reliability analysis was conducted for beams for a fire exposure of 120 min, considering the charring rates observed through the analysis and simulating the fire insulations. Results show that the charring rate of GLT made with spruce pine timber varied between 0.43 and 0.81 mm/min, with a mean rate of 0.7 mm/min, aligning with both Australian and European standards. However, considering timber density and moisture content, the charring rates in Australian standards were conservative. The study also found that structural capacity significantly degrades under fire, with a 22 % reduction in flexural stiffness after 120 min of exposure. Additionally, GLT beams can safely function for 30 min under 75 % of their design moment capacity and for 60 min under 50 % capacity.

Resilient Cities and StructuresVol. 4(1)
Federation University (AU), University of Waterloo (CA), Clinical Research Consultants (United States) (US), Swinburne University of Technology (AU), RMIT University (AU)
Openalex Percentile: Top 8%
Wood Treatment and Properties
4.03
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.