Fault Location Method Based on CNN-BiLSTM-Attention for locating Single-phase Ground Fault in Active distribution

The increasing integration of distributed generation (DG) into the distribution network has led to greater complexity in power flow distribution and transient current characteristics during single-phase grounding faults. As a result, traditional fault location methods are no longer sufficient. Adapting existing fault location methods to accommodate changing permeability has become an urgent issue. In response, a fault location method utilizing a convolutional neural network (CNN) and bidirectional long short-term memory (BiLSTM) network is proposed. The CNN is used to extract detailed longitudinal features from fault zero sequence current data at a specific time, compressing the data length to reduce subsequent network training parameters. Additionally, a cascade network with BiLSTM as its core is constructed to capture historical horizontal features of fault data during the fault evolution process. An Attention mechanism is integrated to ensure that the model focuses on changes in fault time and location data, thereby enhancing fault location accuracy. The simulation results demonstrate that the proposed method is capable of accurately identifying single-phase grounding faults, offering high precision and robustness in positioning, and exhibiting strong adaptability across various permeability fault scenarios.

Authors

Institutions

Publication Details

Published
2024-11-03
DOI
https://doi.org/10.1109/iecon55916.2024.10905438
Primary Topic
Power Systems Fault Detection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Fault Location Method Based on CNN-BiLSTM-Attention for locating Single-phase Ground Fault in Active distribution

Wei Zhang, Liming Xue, Kaiyu Yang, Yirui Sun
Power Systems Fault Detection
article

Fault Location Method Based on CNN-BiLSTM-Attention for locating Single-phase Ground Fault in Active distribution

Wei Zhang, Liming Xue, Kaiyu Yang, Yirui Sun
article en

Abstract

The increasing integration of distributed generation (DG) into the distribution network has led to greater complexity in power flow distribution and transient current characteristics during single-phase grounding faults. As a result, traditional fault location methods are no longer sufficient. Adapting existing fault location methods to accommodate changing permeability has become an urgent issue. In response, a fault location method utilizing a convolutional neural network (CNN) and bidirectional long short-term memory (BiLSTM) network is proposed. The CNN is used to extract detailed longitudinal features from fault zero sequence current data at a specific time, compressing the data length to reduce subsequent network training parameters. Additionally, a cascade network with BiLSTM as its core is constructed to capture historical horizontal features of fault data during the fault evolution process. An Attention mechanism is integrated to ensure that the model focuses on changes in fault time and location data, thereby enhancing fault location accuracy. The simulation results demonstrate that the proposed method is capable of accurately identifying single-phase grounding faults, offering high precision and robustness in positioning, and exhibiting strong adaptability across various permeability fault scenarios.

Northeast Electric Power University (CN)
Climate action
Openalex Percentile: Top 65%
Power Systems Fault Detection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.