Zonotopic fault detection for 2-D FMLSS systems with adaptively event-triggered mechanism

This paper studies zonotopic fault detection (FD) for two-dimensional (2-D) FMLSS systems with adaptively event-triggered mechanism. The exogenous disturbance and measurement noise are assumed to be unknown-but-bounded (UBB) for the 2-D systems. The adaptively event-triggered mechanism is utilized for the first time in 2-D FMLSS systems to save limited communication resource. The generated residual signal is robust against external disturbance and measurement noise, and sensitive to fault by designing a L<inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">∞</inf>/H<inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">∞</inf> fault detection observer (FDO). Subsequently, based on the obtained FDO, a zonotopic residual evaluation scheme is framed subjected to the impacts of event-triggered scheme, noise and disturbance. Finally, a numerical example is provided to certify the validity of the proposed adaptively event-triggered based on zonotopic fault detection method.

Authors

Institutions

Publication Details

Published
2024-11-03
DOI
https://doi.org/10.1109/iecon55916.2024.10905161
Primary Topic
Fault Detection and Control Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Zonotopic fault detection for 2-D FMLSS systems with adaptively event-triggered mechanism

Liu Xiang Yang, Zhihong Zhao
Fault Detection and Control Systems
article

Zonotopic fault detection for 2-D FMLSS systems with adaptively event-triggered mechanism

Liu Xiang Yang, Zhihong Zhao
article en

Abstract

This paper studies zonotopic fault detection (FD) for two-dimensional (2-D) FMLSS systems with adaptively event-triggered mechanism. The exogenous disturbance and measurement noise are assumed to be unknown-but-bounded (UBB) for the 2-D systems. The adaptively event-triggered mechanism is utilized for the first time in 2-D FMLSS systems to save limited communication resource. The generated residual signal is robust against external disturbance and measurement noise, and sensitive to fault by designing a L<inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">∞</inf>/H<inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">∞</inf> fault detection observer (FDO). Subsequently, based on the obtained FDO, a zonotopic residual evaluation scheme is framed subjected to the impacts of event-triggered scheme, noise and disturbance. Finally, a numerical example is provided to certify the validity of the proposed adaptively event-triggered based on zonotopic fault detection method.

Ningbo University of Technology (CN), Harbin Institute of Technology (CN)
Climate action
Openalex Percentile: Top 65%
Fault Detection and Control Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Zonotopic fault detection for 2-D FMLSS systems with adaptively event-triggered mechanism — Liu Xiang Yang, Zhihong Zhao · (2024) | TGRS Research Map | TGRS