Analysis of Converter Valve-Side Single-Phase-to-Ground Faults in Symmetrical Monopolar MMCs

Converter valve-side single-phase-to-ground (SPG) faults are among the most critical issues affecting the secure operation of modular multilevel converters (MMCs). However, the fault characteristics of these faults in symmetrical monopolar MMCs have not been thoroughly explored. This paper aims to fill this gay by theoretically investigating SPG faults in such systems. The analysis considers various influencing factors, including MMC grounding schemes and dc line types. The findings demonstrate that valve-side SPG faults cause dc voltage oscillations and therefore, large discharging currents from the distributed capacitors of dc lines. These scenarios are examined through mathematical analyses and verified through simulations of a generic MMC-HVDC system using PSCAD/EMTDC. The results accurately reveal the fault behaviors under different system conditions, providing valuable insights for the design of protection systems and insulation coordination for internal ac grounding faults in MMC stations.

Authors

Institutions

Publication Details

Published
2024-11-03
DOI
https://doi.org/10.1109/iecon55916.2024.10905643
Citations
1
Primary Topic
HVDC Systems and Fault Protection
Type
article
Field-Weighted Citation Impact
0.21
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Analysis of Converter Valve-Side Single-Phase-to-Ground Faults in Symmetrical Monopolar MMCs

Pingyang Sun, Sahar Pirooz Azad, Georgios Konstantinou, Gen Li
1 citations
HVDC Systems and Fault Protection
0.21
article

Analysis of Converter Valve-Side Single-Phase-to-Ground Faults in Symmetrical Monopolar MMCs

Pingyang Sun, Sahar Pirooz Azad, Georgios Konstantinou, Gen Li
article en
1 citations

Abstract

Converter valve-side single-phase-to-ground (SPG) faults are among the most critical issues affecting the secure operation of modular multilevel converters (MMCs). However, the fault characteristics of these faults in symmetrical monopolar MMCs have not been thoroughly explored. This paper aims to fill this gay by theoretically investigating SPG faults in such systems. The analysis considers various influencing factors, including MMC grounding schemes and dc line types. The findings demonstrate that valve-side SPG faults cause dc voltage oscillations and therefore, large discharging currents from the distributed capacitors of dc lines. These scenarios are examined through mathematical analyses and verified through simulations of a generic MMC-HVDC system using PSCAD/EMTDC. The results accurately reveal the fault behaviors under different system conditions, providing valuable insights for the design of protection systems and insulation coordination for internal ac grounding faults in MMC stations.

University of Waterloo (CA), UNSW Sydney (AU), Technical University of Denmark (DK)
Openalex Percentile: Top 43%
HVDC Systems and Fault Protection
0.21
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.