Analysis of Economic Losses From Phase Imbalance in a Wastewater Treatment Facility

Phase imbalance is a phenomenon in which the three phases of an electrical system differ by more than 10% in magnitude and/or phase. Most electrical systems are capable of operating through this imbalance for long periods of time without noticeable failures. However, prolonged imbalance will cause sustained wear to the motor windings and increases in electric utility charges. This paper presents a method for calculating the economic loss within the electric utility charges to provide justifications for electrical infrastructure projects. The paper utilizes effective power and positive sequence components to calculate the percent phase imbalance. An example project using real data from a wastewater treatment facility is provided to demonstrate the appropriate application of the calculations. The key findings are a reduction in electric utility charges by up to 20% through phase balancing systems.

Authors

Institutions

Publication Details

Published
2024-11-03
DOI
https://doi.org/10.1109/iecon55916.2024.10905591
Primary Topic
Water-Energy-Food Nexus Studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Analysis of Economic Losses From Phase Imbalance in a Wastewater Treatment Facility

James Cale, Martin Wagner
Water-Energy-Food Nexus Studies
article

Analysis of Economic Losses From Phase Imbalance in a Wastewater Treatment Facility

James Cale, Martin Wagner
article en

Abstract

Phase imbalance is a phenomenon in which the three phases of an electrical system differ by more than 10% in magnitude and/or phase. Most electrical systems are capable of operating through this imbalance for long periods of time without noticeable failures. However, prolonged imbalance will cause sustained wear to the motor windings and increases in electric utility charges. This paper presents a method for calculating the economic loss within the electric utility charges to provide justifications for electrical infrastructure projects. The paper utilizes effective power and positive sequence components to calculate the percent phase imbalance. An example project using real data from a wastewater treatment facility is provided to demonstrate the appropriate application of the calculations. The key findings are a reduction in electric utility charges by up to 20% through phase balancing systems.

Colorado State University (US)
Clean water and sanitation
Openalex Percentile: Top 73%
Water-Energy-Food Nexus Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.