Assessment of High-Frequency Common-Mode Voltage for Winding Insulation Monitoring based on Novel Voltage Step Excitation

Due to the fast slew rates of modern power switching devices, inverter-fed motors experience intensified insulation stress. In addition, inverter switching with fast slew rates excites several high frequencies including multiple antiresonance frequencies of the winding and supply cable, further suffocating winding insulation at localized winding spots. As a result of the wide range of excited frequencies, high frequency currents and voltages can be used to track insulation state. In particular, the voltage at the star point of inverter-fed motors can show the degree of motor ground-wall insulation aging. However, accessing star point might not be feasible in some applications. In this paper, a special switching scheme is proposed, turning the star neutral voltage visible at the terminal voltage without the need for additional equipment or disassembling. Via solely sensing the terminal voltage, ground-wall insulation will be monitored. In addition, the proposed switching scheme elicits additional motor resonance modes, which extends the variety of current and voltage analysis for insulation condition monitoring. Experimental validation using an inverter-fed 2MW medium-voltage traction induction motor is provided.

Authors

Institutions

Publication Details

Published
2024-11-03
DOI
https://doi.org/10.1109/iecon55916.2024.10905533
Citations
2
Primary Topic
High voltage insulation and dielectric phenomena
Type
article
Field-Weighted Citation Impact
0.23
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Assessment of High-Frequency Common-Mode Voltage for Winding Insulation Monitoring based on Novel Voltage Step Excitation

Eduardo Rodriguez Montero, Markus Vogelsberger, Thomas M. Wolbank
2 citations
High voltage insulation and dielectric phenomena
0.23
article

Assessment of High-Frequency Common-Mode Voltage for Winding Insulation Monitoring based on Novel Voltage Step Excitation

Eduardo Rodriguez Montero, Markus Vogelsberger, Thomas M. Wolbank
article en
2 citations

Abstract

Due to the fast slew rates of modern power switching devices, inverter-fed motors experience intensified insulation stress. In addition, inverter switching with fast slew rates excites several high frequencies including multiple antiresonance frequencies of the winding and supply cable, further suffocating winding insulation at localized winding spots. As a result of the wide range of excited frequencies, high frequency currents and voltages can be used to track insulation state. In particular, the voltage at the star point of inverter-fed motors can show the degree of motor ground-wall insulation aging. However, accessing star point might not be feasible in some applications. In this paper, a special switching scheme is proposed, turning the star neutral voltage visible at the terminal voltage without the need for additional equipment or disassembling. Via solely sensing the terminal voltage, ground-wall insulation will be monitored. In addition, the proposed switching scheme elicits additional motor resonance modes, which extends the variety of current and voltage analysis for insulation condition monitoring. Experimental validation using an inverter-fed 2MW medium-voltage traction induction motor is provided.

TU Wien (AT)
Affordable and clean energy
Openalex Percentile: Top 49%
High voltage insulation and dielectric phenomena
0.23
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.