Fault-Tolerant Current and Reactive Power Predictive Control in a Multi-Modular 2-Level Indirect Matrix Converter

This paper studied the design of a predictive current control strategy with fault tolerance and reactive power minimization applied to a multi-modular topology based on indirect 2-level matrix converters fed by a six-phase generator. The control algorithm of the proposed strategy involves coupled current signals to perform error compensation between the converter modules, aiming to address potential system faults while maintaining reactive power close to zero. The results, obtained through simulation, were evaluated considering each module’s input and output currents and the final load current, as well as reactive power minimization, incorporating the obtained values of total harmonic distortion and mean squared error. The behaviour was analyzed in steady-state and transient conditions, with the system operating nominally and under fault conditions. The results demonstrate the effectiveness and good performance of the proposed strategy with the utilized topology, achieving a satisfactory response to faults through compensation and constant reactive power minimization.

Authors

Institutions

Publication Details

Published
2024-11-03
DOI
https://doi.org/10.1109/iecon55916.2024.10905769
Primary Topic
Multilevel Inverters and Converters
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Fault-Tolerant Current and Reactive Power Predictive Control in a Multi-Modular 2-Level Indirect Matrix Converter

Sérgio Toledo, Jorge Rodas, Edgar Maqueda, David Caballero et al.
Multilevel Inverters and Converters
article

Fault-Tolerant Current and Reactive Power Predictive Control in a Multi-Modular 2-Level Indirect Matrix Converter

Sérgio Toledo, Jorge Rodas, Edgar Maqueda, David Caballero, Marco Rivera, Raúl Gregor, Fabian Palacios-Pereira
article en

Abstract

This paper studied the design of a predictive current control strategy with fault tolerance and reactive power minimization applied to a multi-modular topology based on indirect 2-level matrix converters fed by a six-phase generator. The control algorithm of the proposed strategy involves coupled current signals to perform error compensation between the converter modules, aiming to address potential system faults while maintaining reactive power close to zero. The results, obtained through simulation, were evaluated considering each module’s input and output currents and the final load current, as well as reactive power minimization, incorporating the obtained values of total harmonic distortion and mean squared error. The behaviour was analyzed in steady-state and transient conditions, with the system operating nominally and under fault conditions. The results demonstrate the effectiveness and good performance of the proposed strategy with the utilized topology, achieving a satisfactory response to faults through compensation and constant reactive power minimization.

University of Nottingham (GB), Universidad Nacional de Asunción (PY)
Universidad Nacional de Asunción, Agencia Nacional de Investigación y Desarrollo
Affordable and clean energy
Openalex Percentile: Top 74%
Multilevel Inverters and Converters
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Fault-Tolerant Current and Reactive Power Predictive Control in a Multi-Modular 2-Level Indirect Matrix Converter — Sérgio Toledo, Jorge Rodas, et al. · (2024) | TGRS Research Map | TGRS