Controller Design for Water Treatment Plants Using Data-Driven Control

This study explores methods for improving energy efficiency in wastewater treatment facilities to address the pressure of rising electricity tariffs. As the energy consumption by water treatment facilities accounting for about 50% of the total electricity consumption in wastewater treatment facilities, particular attention is paid to the energy utilization of blowers within water treatment facilities [1], [2]. The aim is to achieve appropriate control of aeration equipment based on the facility’s conditions and environment, without relying on plant models but using data-driven control. This approach addresses the problem of excessive electricity consumption in current scenarios that rely on manual control or simple control loops. By employing VRFT for the PID controller parameter tuning, a successful improvement in the target response performance was achieved. The proposed method achieved an error in the DO response comparable to that of conventional methods and reduced the operating costs of aeration at wastewater treatment plants by about 12%.

Authors

Institutions

Publication Details

Published
2024-11-03
DOI
https://doi.org/10.1109/iecon55916.2024.10905611
Citations
1
Primary Topic
Fault Detection and Control Systems
Type
article
Field-Weighted Citation Impact
0.33
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Controller Design for Water Treatment Plants Using Data-Driven Control

Masaki Furukawa, Yasutaka Fujimoto
1 citations
Fault Detection and Control Systems
0.33
article

Controller Design for Water Treatment Plants Using Data-Driven Control

Masaki Furukawa, Yasutaka Fujimoto
article en
1 citations

Abstract

This study explores methods for improving energy efficiency in wastewater treatment facilities to address the pressure of rising electricity tariffs. As the energy consumption by water treatment facilities accounting for about 50% of the total electricity consumption in wastewater treatment facilities, particular attention is paid to the energy utilization of blowers within water treatment facilities [1], [2]. The aim is to achieve appropriate control of aeration equipment based on the facility’s conditions and environment, without relying on plant models but using data-driven control. This approach addresses the problem of excessive electricity consumption in current scenarios that rely on manual control or simple control loops. By employing VRFT for the PID controller parameter tuning, a successful improvement in the target response performance was achieved. The proposed method achieved an error in the DO response comparable to that of conventional methods and reduced the operating costs of aeration at wastewater treatment plants by about 12%.

Yokohama National University (JP)
Clean water and sanitation
Openalex Percentile: Top 36%
Fault Detection and Control Systems
0.33
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.