Bipolar Duty Cycle Control for Dual Side LCC Compensated Inductive Power Transfer System for Wide Output Voltage Range

This paper proposes a hybrid phase shift control strategy for dual side inductor-capacitor-capacitor compensated inductive power transfer (IPT) system to achieve a wide output voltage regulation range. The first-order harmonic time domain model is used to compute the inverter output voltage. Then, models of system operation in constant voltage (CV) and constant current (CC) modes are developed to analyze the efficiency of the battery charging process. The designed controller loops are validated for a 1 kW MATLAB Simulink model. Results show that a maximum efficiency of 93.80% is achieved at full load conditions, and the proposed control strategy achieves zero voltage switching (ZVS) in more switches than the conventional control method.

Authors

Institutions

Publication Details

Published
2024-11-03
DOI
https://doi.org/10.1109/iecon55916.2024.10905524
Primary Topic
Wireless Power Transfer Systems
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Bipolar Duty Cycle Control for Dual Side LCC Compensated Inductive Power Transfer System for Wide Output Voltage Range

Dharavath Kishan, Andrii Chub, Marupuru Vinod
Wireless Power Transfer Systems
article

Bipolar Duty Cycle Control for Dual Side LCC Compensated Inductive Power Transfer System for Wide Output Voltage Range

Dharavath Kishan, Andrii Chub, Marupuru Vinod
article en

Abstract

This paper proposes a hybrid phase shift control strategy for dual side inductor-capacitor-capacitor compensated inductive power transfer (IPT) system to achieve a wide output voltage regulation range. The first-order harmonic time domain model is used to compute the inverter output voltage. Then, models of system operation in constant voltage (CV) and constant current (CC) modes are developed to analyze the efficiency of the battery charging process. The designed controller loops are validated for a 1 kW MATLAB Simulink model. Results show that a maximum efficiency of 93.80% is achieved at full load conditions, and the proposed control strategy achieves zero voltage switching (ZVS) in more switches than the conventional control method.

Tallinn University of Technology (EE), National Institute of Technology Karnataka (IN)
Ministry of Education
Affordable and clean energy
Openalex Percentile: Top 74%
Wireless Power Transfer Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Bipolar Duty Cycle Control for Dual Side LCC Compensated Inductive Power Transfer System for Wide Output Voltage Range — Dharavath Kishan, Andrii Chub, et al. · (2024) | TGRS Research Map | TGRS