Actual Circuit Verification of LC Series Resonant Converter with Power Factor Control for Effective Power in Load regulation

Resonant converters are poor stability about load reguration. New control methods have been proposed to stabilize resonant converters versus load variations. This paper describes the LC series resonant converter using a power factor control with stable control characteristic for load regulation. The proposed control adjusts the power factor that determined by primary current and voltage. Previous research proposed phase shift control method for power factor. This method controls the power factor by using the voltage across the resonant capacitor. The problem with this method is that it assumes the resonant capacitor voltage is sinusoidal when controlling the power factor. Therefore, power factor control becomes more difficult when the waveform is distorted. This research proposed a new power factor control method to address this problem in simulations. Hence, this paper shows that the proposed method has stable control characteristic versus load regulation even in actual circuits.

Authors

Institutions

Publication Details

Published
2024-11-03
DOI
https://doi.org/10.1109/iecon55916.2024.10905184
Primary Topic
Advanced DC-DC Converters
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Actual Circuit Verification of LC Series Resonant Converter with Power Factor Control for Effective Power in Load regulation

Akito Nakagaki, Eiji Hiraki, Kazuhiro Umetani, Masataka Ishihara et al.
1 links
Advanced DC-DC Converters
article

Actual Circuit Verification of LC Series Resonant Converter with Power Factor Control for Effective Power in Load regulation

Akito Nakagaki, Eiji Hiraki, Kazuhiro Umetani, Masataka Ishihara, Yuto Yoshimura
article en

Abstract

Resonant converters are poor stability about load reguration. New control methods have been proposed to stabilize resonant converters versus load variations. This paper describes the LC series resonant converter using a power factor control with stable control characteristic for load regulation. The proposed control adjusts the power factor that determined by primary current and voltage. Previous research proposed phase shift control method for power factor. This method controls the power factor by using the voltage across the resonant capacitor. The problem with this method is that it assumes the resonant capacitor voltage is sinusoidal when controlling the power factor. Therefore, power factor control becomes more difficult when the waveform is distorted. This research proposed a new power factor control method to address this problem in simulations. Hence, this paper shows that the proposed method has stable control characteristic versus load regulation even in actual circuits.

Okayama University (JP)
Affordable and clean energy
Openalex Percentile: Top 74%
Advanced DC-DC Converters
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.