Three-phase Voltage PWM Rectifier Based on EID and Improved ADRC Control

In high-precision occasions, three-phase voltage PWM rectifier based on conventional voltage-current dual closed-loop control suffer from current harmonics and poor interference immunity. In order to effectively alleviate the above problems, partial feedback linearisation control is introduced in the current inner loop, and equivalent input disturbance (EID) based active disturbance rejection control (ADRC) control is introduced in the voltage outer loop, and the fal function is changed to qin function to solve the jitter problem that occurs when the inflection point is not smooth. Firstly, the mathematical model of the three-phase voltage PWM rectifier in the dq coordinate system is established, and its underactuated characteristics are analysed; Then, the feedback linearisation controller is designed with current as the actuated variables, and the improved EID\ADRC controller is designed with voltage as the underactuated variable; Finally, simulation experiments are carried out by Matlab/Simulink to verify the feasibility of the proposed method.

Authors

Institutions

Publication Details

Published
2024-11-03
DOI
https://doi.org/10.1109/iecon55916.2024.10905241
Citations
1
Primary Topic
Advanced Algorithms and Applications
Type
article
Field-Weighted Citation Impact
0.33

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Three-phase Voltage PWM Rectifier Based on EID and Improved ADRC Control

Junjie Lu, Wei Wang, Zixin Huang
1 citations
Advanced Algorithms and Applications
0.33
article

Three-phase Voltage PWM Rectifier Based on EID and Improved ADRC Control

Junjie Lu, Wei Wang, Zixin Huang
article en
1 citations

Abstract

In high-precision occasions, three-phase voltage PWM rectifier based on conventional voltage-current dual closed-loop control suffer from current harmonics and poor interference immunity. In order to effectively alleviate the above problems, partial feedback linearisation control is introduced in the current inner loop, and equivalent input disturbance (EID) based active disturbance rejection control (ADRC) control is introduced in the voltage outer loop, and the fal function is changed to qin function to solve the jitter problem that occurs when the inflection point is not smooth. Firstly, the mathematical model of the three-phase voltage PWM rectifier in the dq coordinate system is established, and its underactuated characteristics are analysed; Then, the feedback linearisation controller is designed with current as the actuated variables, and the improved EID\ADRC controller is designed with voltage as the underactuated variable; Finally, simulation experiments are carried out by Matlab/Simulink to verify the feasibility of the proposed method.

Wuhan Institute of Technology (CN)
National Natural Science Foundation of China, Wuhan Institute of Technology, Wuhan Textile University, Nature
Affordable and clean energy
Openalex Percentile: Top 36%
Advanced Algorithms and Applications
0.33
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Three-phase Voltage PWM Rectifier Based on EID and Improved ADRC Control — Junjie Lu, Wei Wang, et al. · (2024) | TGRS Research Map | TGRS