Online Monitoring of Interturn Short Circuit Current in PMSMs

This paper extends the previously published parameter estimation-based approach to interturn short circuit diagnostics in permanent magnet synchronous motors by real-time monitoring of hidden machine states after fault occurrence. The designed monitoring method relies on an adaptive formulation of the Kalman filter, which assumes interdependence between measurement and process noise variables. A variable forgetting factor not only mitigates the impact of the process model uncertainty but also facilitates the simultaneous operation of the monitoring algorithm and fault indicator estimation. Furthermore, contributions of fault current and healthy machine model to stationary reference frame currents are estimated from an advanced discrete-time motor description reflecting a stator winding arrangement inside a motor’s case. The monitoring algorithm is validated in steady state, torque load transient, and velocity transient laboratory experiments with diverse fault severity values.

Authors

Institutions

Publication Details

Published
2024-11-03
DOI
https://doi.org/10.1109/iecon55916.2024.10905190
Citations
1
Primary Topic
Non-Destructive Testing Techniques
Type
article
Field-Weighted Citation Impact
0.21

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Online Monitoring of Interturn Short Circuit Current in PMSMs

Petr Bláha, Lukas Zezula
1 citations
Non-Destructive Testing Techniques
0.21
article

Online Monitoring of Interturn Short Circuit Current in PMSMs

Petr Bláha, Lukas Zezula
article en
1 citations

Abstract

This paper extends the previously published parameter estimation-based approach to interturn short circuit diagnostics in permanent magnet synchronous motors by real-time monitoring of hidden machine states after fault occurrence. The designed monitoring method relies on an adaptive formulation of the Kalman filter, which assumes interdependence between measurement and process noise variables. A variable forgetting factor not only mitigates the impact of the process model uncertainty but also facilitates the simultaneous operation of the monitoring algorithm and fault indicator estimation. Furthermore, contributions of fault current and healthy machine model to stationary reference frame currents are estimated from an advanced discrete-time motor description reflecting a stator winding arrangement inside a motor’s case. The monitoring algorithm is validated in steady state, torque load transient, and velocity transient laboratory experiments with diverse fault severity values.

Central European Institute of Technology (CZ), Brno University of Technology (CZ)
Ministry of Education
Climate action
Openalex Percentile: Top 48%
Non-Destructive Testing Techniques
0.21
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.