DC Fault Detection Using Time Derivative of High-Pass Filter Response in MTDC Systems

In the DC fault event, DC link capacitors immediately discharge a colossal current of high frequency. These large currents of high frequencies can instantly damage the components attached to the DC transmission system. Therefore, a rapid and robust DC fault detection topology is necessary, facilitating protection coordination in forthcoming Multi-Terminal Direct Current (MTDC) systems. This study introduces a novel fault detection technique using the time derivative of the High Pass Filter (HPF) response to identify fault currents in just a few microseconds (µs). This topology enables protection coordination for modern MTDC systems. Furthermore, this technique can identify different types of DC faults and remains unaffected by AC faults and load variation.

Authors

Institutions

Publication Details

Published
2024-11-03
DOI
https://doi.org/10.1109/iecon55916.2024.10905437
Citations
1
Primary Topic
HVDC Systems and Fault Protection
Type
article
Field-Weighted Citation Impact
0.21
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

DC Fault Detection Using Time Derivative of High-Pass Filter Response in MTDC Systems

Shuhab D. Khan, Nirmal‐Kumar C. Nair, Abhisek Ukil
1 citations
HVDC Systems and Fault Protection
0.21
article

DC Fault Detection Using Time Derivative of High-Pass Filter Response in MTDC Systems

Shuhab D. Khan, Nirmal‐Kumar C. Nair, Abhisek Ukil
article en
1 citations

Abstract

In the DC fault event, DC link capacitors immediately discharge a colossal current of high frequency. These large currents of high frequencies can instantly damage the components attached to the DC transmission system. Therefore, a rapid and robust DC fault detection topology is necessary, facilitating protection coordination in forthcoming Multi-Terminal Direct Current (MTDC) systems. This study introduces a novel fault detection technique using the time derivative of the High Pass Filter (HPF) response to identify fault currents in just a few microseconds (µs). This topology enables protection coordination for modern MTDC systems. Furthermore, this technique can identify different types of DC faults and remains unaffected by AC faults and load variation.

University of Auckland (NZ)
Climate action
Openalex Percentile: Top 43%
HVDC Systems and Fault Protection
0.21
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

DC Fault Detection Using Time Derivative of High-Pass Filter Response in MTDC Systems — Shuhab D. Khan, Nirmal‐Kumar C. Nair, et al. · (2024) | TGRS Research Map | TGRS