Synthesis of Power Supply Generator Circuit for X-Ray Device with Enhanced Performance

An X-ray medical apparatus requires a high voltage to operate and shall be produced from a domestic 3-phase or 1-phase AC supply in hospitals. Along with this comes a power quality issue, as this medical device has become common. Following a typical X-ray datasheet, the voltage level must increase from 400/415 volts mains to 120 kV. Due to the above reason, several stages are required to boost the voltage level to the required level. This leads to the heavy size of the equipment, increased losses, and poor power quality. This paper proposes a methodology to implement the power supply generator circuit for an X-ray device that adopts 1) a 3-phase Boost PFC (Power Factor Correction) rectifier, 2) a High-frequency series resonant inverter, and 3) a Voltage multiplier circuit. ZCS (Zero Current Switching) has been adopted to reduce switching losses due to high-frequency switching frequency.

Authors

Institutions

Publication Details

Published
2024-11-03
DOI
https://doi.org/10.1109/iecon55916.2024.10905379
Primary Topic
Advanced Materials and Semiconductor Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Synthesis of Power Supply Generator Circuit for X-Ray Device with Enhanced Performance

K. Gopakumar, L. Umanand, Nair Syam Sundar S.
Advanced Materials and Semiconductor Technologies
article

Synthesis of Power Supply Generator Circuit for X-Ray Device with Enhanced Performance

K. Gopakumar, L. Umanand, Nair Syam Sundar S.
article en

Abstract

An X-ray medical apparatus requires a high voltage to operate and shall be produced from a domestic 3-phase or 1-phase AC supply in hospitals. Along with this comes a power quality issue, as this medical device has become common. Following a typical X-ray datasheet, the voltage level must increase from 400/415 volts mains to 120 kV. Due to the above reason, several stages are required to boost the voltage level to the required level. This leads to the heavy size of the equipment, increased losses, and poor power quality. This paper proposes a methodology to implement the power supply generator circuit for an X-ray device that adopts 1) a 3-phase Boost PFC (Power Factor Correction) rectifier, 2) a High-frequency series resonant inverter, and 3) a Voltage multiplier circuit. ZCS (Zero Current Switching) has been adopted to reduce switching losses due to high-frequency switching frequency.

Indian Institute of Science Bangalore (IN)
Affordable and clean energy
Openalex Percentile: Top 83%
Advanced Materials and Semiconductor Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Synthesis of Power Supply Generator Circuit for X-Ray Device with Enhanced Performance — K. Gopakumar, L. Umanand, et al. · (2024) | TGRS Research Map | TGRS