Selective Harmonic Control in Two-Level Inverters with Three Switching Angles using a Graphical 3D to 2D Approach

In power electronic systems, the management of harmonic distortion is paramount for ensuring both efficiency and reliability. This study introduces a methodology involving three switching events per quarter cycle in a three-phase, two-level voltage source inverter (VSI) to eliminate three specific harmonics, while also attenuating several others. By strategically implementing three switches per quarter cycle, lower-order harmonics are effectively targeted for elimination and mitigation in accordance with grid codes, thereby contributing to the reduction of Total Harmonic Distortion (THD). MATLAB simulations are employed to graphically derive and validate the optimal switching angles, demonstrating the efficacy of the proposed method across various modulation indices. The results indicate that maintaining a band gap of (±5%) can attenuate harmonics up to the 23<sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">rd</sup> order, thereby enhancing overall power quality and ensuring compliance with harmonic standards.

Authors

Institutions

Publication Details

Published
2024-11-03
DOI
https://doi.org/10.1109/iecon55916.2024.10905774
Primary Topic
Electric Motor Design and Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Selective Harmonic Control in Two-Level Inverters with Three Switching Angles using a Graphical 3D to 2D Approach

Pratik Kalkal, A. V. Ravi Teja, Soumava Mukherjee
Electric Motor Design and Analysis
article

Selective Harmonic Control in Two-Level Inverters with Three Switching Angles using a Graphical 3D to 2D Approach

Pratik Kalkal, A. V. Ravi Teja, Soumava Mukherjee
article en

Abstract

In power electronic systems, the management of harmonic distortion is paramount for ensuring both efficiency and reliability. This study introduces a methodology involving three switching events per quarter cycle in a three-phase, two-level voltage source inverter (VSI) to eliminate three specific harmonics, while also attenuating several others. By strategically implementing three switches per quarter cycle, lower-order harmonics are effectively targeted for elimination and mitigation in accordance with grid codes, thereby contributing to the reduction of Total Harmonic Distortion (THD). MATLAB simulations are employed to graphically derive and validate the optimal switching angles, demonstrating the efficacy of the proposed method across various modulation indices. The results indicate that maintaining a band gap of (±5%) can attenuate harmonics up to the 23<sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">rd</sup> order, thereby enhancing overall power quality and ensuring compliance with harmonic standards.

Indian Institute of Technology Ropar (IN)
Affordable and clean energy
Openalex Percentile: Top 74%
Electric Motor Design and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.