Improved Post-Fault Recovery in MMC-HVDC Networks using Enhanced Active Damping

High-Voltage Direct Current (HVDC) transmission with Modular Multi-level Converter (MMC) - Bipolar Point-to-Point (BPP) configuration is gaining traction as a solution for integrating renewable energy sources into future power grids. However, one critical challenge associated with MMC-BPP systems is the occurrence and mitigation of oscillations on the DC side. These oscillations can arise due to various factors, including interactions between the AC and DC systems, converter de-blocking after fault events, and the dynamic behavior of connected power sources. The research work presented in this paper addresses a gap by investigating and mitigating oscillations specifically occurring during post-fault converter de-blocking. An enhanced active damping method is proposed that achieves a substantial reduction of these oscillations, ensuring improved system stability during this critical phase. Furthermore, a meticulous parametric sensitivity analysis is conducted on a four-terminal MMC-BPP test system using a real-time simulator to extract valuable insights into the damping method’s effectiveness under various operating conditions.

Authors

Institutions

Publication Details

Published
2024-11-03
DOI
https://doi.org/10.1109/iecon55916.2024.10905603
Primary Topic
HVDC Systems and Fault Protection
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Improved Post-Fault Recovery in MMC-HVDC Networks using Enhanced Active Damping

Peter Pálenský, José L. Rueda, Monika Sharma
2 links
HVDC Systems and Fault Protection
article

Improved Post-Fault Recovery in MMC-HVDC Networks using Enhanced Active Damping

Peter Pálenský, José L. Rueda, Monika Sharma
article en

Abstract

High-Voltage Direct Current (HVDC) transmission with Modular Multi-level Converter (MMC) - Bipolar Point-to-Point (BPP) configuration is gaining traction as a solution for integrating renewable energy sources into future power grids. However, one critical challenge associated with MMC-BPP systems is the occurrence and mitigation of oscillations on the DC side. These oscillations can arise due to various factors, including interactions between the AC and DC systems, converter de-blocking after fault events, and the dynamic behavior of connected power sources. The research work presented in this paper addresses a gap by investigating and mitigating oscillations specifically occurring during post-fault converter de-blocking. An enhanced active damping method is proposed that achieves a substantial reduction of these oscillations, ensuring improved system stability during this critical phase. Furthermore, a meticulous parametric sensitivity analysis is conducted on a four-terminal MMC-BPP test system using a real-time simulator to extract valuable insights into the damping method’s effectiveness under various operating conditions.

Delft University of Technology (NL)
HORIZON EUROPE Framework Programme
Affordable and clean energy
Openalex Percentile: Top 74%
HVDC Systems and Fault Protection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Improved Post-Fault Recovery in MMC-HVDC Networks using Enhanced Active Damping — Peter Pálenský, José L. Rueda, et al. · (2024) | TGRS Research Map | TGRS