AC Crowbar Protection Scheme for Medium-Voltage Solid-State Transformers

Solid-State Transformers (SSTs) are gaining popularity in a number of applications to directly interface with the medium-voltage (MV) AC grid. As SSTs fundamentally consist of power electronic semiconductor devices, a key challenge is to design SST systems capable of withstanding the various overvoltage conditions observed on the MVAC grid such as lightning surges, switching surges and transient overvoltage conditions. This paper proposes a protection scheme that uses an AC crowbar in combination with existing MV overvoltage protection devices to offer robust protection to SSTs. The AC crowbar operation is analyzed in conjunction with MV breakers and surge protection equipment and design guidelines are presented for the case of a 13.8kV/1MVA grid-tied SST.

Authors

Institutions

Publication Details

Published
2024-11-03
DOI
https://doi.org/10.1109/iecon55916.2024.10905267
Citations
1
Primary Topic
Electrical Fault Detection and Protection
Type
article
Field-Weighted Citation Impact
0.21
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

AC Crowbar Protection Scheme for Medium-Voltage Solid-State Transformers

Adithyan Vetrivelan, Alex Q. Huang
1 citations
Electrical Fault Detection and Protection
0.21
article

AC Crowbar Protection Scheme for Medium-Voltage Solid-State Transformers

Adithyan Vetrivelan, Alex Q. Huang
article en
1 citations

Abstract

Solid-State Transformers (SSTs) are gaining popularity in a number of applications to directly interface with the medium-voltage (MV) AC grid. As SSTs fundamentally consist of power electronic semiconductor devices, a key challenge is to design SST systems capable of withstanding the various overvoltage conditions observed on the MVAC grid such as lightning surges, switching surges and transient overvoltage conditions. This paper proposes a protection scheme that uses an AC crowbar in combination with existing MV overvoltage protection devices to offer robust protection to SSTs. The AC crowbar operation is analyzed in conjunction with MV breakers and surge protection equipment and design guidelines are presented for the case of a 13.8kV/1MVA grid-tied SST.

The University of Texas at Austin (US)
Affordable and clean energy
Openalex Percentile: Top 43%
Electrical Fault Detection and Protection
0.21
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.