Localized CO2 Corrosion due to Galvanic Effect on the Surface of API 5L X65 Steel in the Presence of Iron Carbonate Corrosion Product

Localized CO2 corrosion is one of the most significant concerns for mild steels used in the oil and gas industry. The formation of iron carbonate on the steel surface under CO2 corrosion conditions can lead to localized corrosion. The degradation of this corrosion product in specific areas, influenced by factors such as fluid velocity, creates a galvanic couple between the protected and unprotected steel surfaces. This study employs the artificial pit method and zero-resistance ammetery technique to investigate this galvanic couple. The effects of temperature, pH, inhibitor, and NaCl salt concentration on the galvanic current density between iron carbonate-covered and bare areas of API 5L X65 carbon steel were examined. Results indicate that high salt concentration, low pH, and lower temperatures increase the galvanic current density between the FeCO3-covered and bare areas.

Authors

Institutions

Publication Details

Journal
Protection of Metals and Physical Chemistry of Surfaces
Published
2024-10-01
DOI
https://doi.org/10.1134/s2070205124702204
Citations
1
Primary Topic
Corrosion Behavior and Inhibition
Type
article
Field-Weighted Citation Impact
0.12
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Localized CO2 Corrosion due to Galvanic Effect on the Surface of API 5L X65 Steel in the Presence of Iron Carbonate Corrosion Product

Mehdi Javidi, Mohammad Amin Sadeghi, Seyed Jabbar Fatemifar
1 citations
Protection of Metals and Physical Chemistry of Surfaces
Corrosion Behavior and Inhibition
0.12
article

Localized CO2 Corrosion due to Galvanic Effect on the Surface of API 5L X65 Steel in the Presence of Iron Carbonate Corrosion Product

Mehdi Javidi, Mohammad Amin Sadeghi, Seyed Jabbar Fatemifar
article en
1 citations

Abstract

Localized CO2 corrosion is one of the most significant concerns for mild steels used in the oil and gas industry. The formation of iron carbonate on the steel surface under CO2 corrosion conditions can lead to localized corrosion. The degradation of this corrosion product in specific areas, influenced by factors such as fluid velocity, creates a galvanic couple between the protected and unprotected steel surfaces. This study employs the artificial pit method and zero-resistance ammetery technique to investigate this galvanic couple. The effects of temperature, pH, inhibitor, and NaCl salt concentration on the galvanic current density between iron carbonate-covered and bare areas of API 5L X65 carbon steel were examined. Results indicate that high salt concentration, low pH, and lower temperatures increase the galvanic current density between the FeCO3-covered and bare areas.

Protection of Metals and Physical Chemistry of SurfacesVol. 60(5)
Shiraz University (IR)
Openalex Percentile: Top 56%
Corrosion Behavior and Inhibition
0.12
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.