Analysis of the Influence of the Adjustment Error of the Differential Phase Polarimeter Analyzer on the Informative Signal Parameters

The purpose of this work is to improve the accuracy of measurements of the optical rotation angle (ORA) by analyzing the effect of the adjustment error of the differential phase polarimeter analyzer. The paper presents the scheme of the differential phase polarimeter used for studying optically active substances. To analyze the effect of the alignment error of the rotating analyzer on the ORA measurement results, mathematical modeling of the process of forming the informative signal in the presence of a deviation from the perpendicular plane of the analyzer relative to the axis of radiation propagation was applied. The results of the study of the influence of the adjustment error on the accuracy of restoring the phase difference of two harmonic signals are presented. The results obtained make it possible to develop the requirements for the adjustment of the elements of the differential phase polarimeter to increase the accuracy of the ORA measurements.

Authors

Institutions

Publication Details

Journal
Optoelectronics Instrumentation and Data Processing
Published
2024-10-01
DOI
https://doi.org/10.3103/s8756699024700729
Primary Topic
Optical measurement and interference techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Analysis of the Influence of the Adjustment Error of the Differential Phase Polarimeter Analyzer on the Informative Signal Parameters

A. I. Yurin, G. N. Vishnyakov, Alexander Golopolosov, V. L. Minaev
Optoelectronics Instrumentation and Data Processing
Optical measurement and interference techniques
article

Analysis of the Influence of the Adjustment Error of the Differential Phase Polarimeter Analyzer on the Informative Signal Parameters

A. I. Yurin, G. N. Vishnyakov, Alexander Golopolosov, V. L. Minaev
article en

Abstract

The purpose of this work is to improve the accuracy of measurements of the optical rotation angle (ORA) by analyzing the effect of the adjustment error of the differential phase polarimeter analyzer. The paper presents the scheme of the differential phase polarimeter used for studying optically active substances. To analyze the effect of the alignment error of the rotating analyzer on the ORA measurement results, mathematical modeling of the process of forming the informative signal in the presence of a deviation from the perpendicular plane of the analyzer relative to the axis of radiation propagation was applied. The results of the study of the influence of the adjustment error on the accuracy of restoring the phase difference of two harmonic signals are presented. The results obtained make it possible to develop the requirements for the adjustment of the elements of the differential phase polarimeter to increase the accuracy of the ORA measurements.

Optoelectronics Instrumentation and Data ProcessingVol. 60(5)
National Research University Higher School of Economics (RU), Bauman Moscow State Technical University (RU), All-Russian Research Institute for Optical and Physical Measurements (RU)
Openalex Percentile: Top 72%
Optical measurement and interference techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Analysis of the Influence of the Adjustment Error of the Differential Phase Polarimeter Analyzer on the Informative Signal Parameters — A. I. Yurin, G. N. Vishnyakov, et al. · Optoelectronics Instrumentation and Data Processing (2024) | TGRS Research Map | TGRS