Blinded prediction of custom-made pelvic implant failure using patient-specific finite element modeling

Additively manufactured, custom-made implants used for reconstruction are a promising treatment following tumor resection. However, failure rates due to mechanical factors remain high when used in the pelvis for even state-of-the-art prosthesis designs. In a collaborative effort between a clinical and an engineering research team, this study evaluated whether patient-specific biomechanical modeling could predict, in a blinded fashion, the mode and location of a clinically-observed mechanical failure. Multiple failure criteria were considered including the risk of bone fracture due to overloading or stress shielding and prosthesis fracture due to overloading or fatigue. The blinded predictions indicated that the risk of fatigue failure in the pubic screws were eight times higher than the most critical ilium screw and two times higher than the most critical cancellous screw. Simulation of stress-shielding during walking matched evidence of osteolysis in the ilium and pubis. Incorporating patient-specific modeling into the custom implant design process may lead to improved durability.

Authors

Institutions

Publication Details

Journal
Medical Engineering & Physics
Published
2025-03-09
DOI
https://doi.org/10.1016/j.medengphy.2025.104321
Citations
1
Primary Topic
Orthopaedic implants and arthroplasty
Type
article
Field-Weighted Citation Impact
2.01

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Blinded prediction of custom-made pelvic implant failure using patient-specific finite element modeling

Yuhui Zhu, Alberto Leardini, Benjamin J. Fregly, Nicholas J. Dunbar et al.
1 citations
Medical Engineering & Physics
Orthopaedic implants and arthroplasty
2.01
article

Blinded prediction of custom-made pelvic implant failure using patient-specific finite element modeling

Yuhui Zhu, Alberto Leardini, Benjamin J. Fregly, Nicholas J. Dunbar, Benedetta Spazzoli, Ata Babazadeh‐Naseri, Claudio Belvedere, Davide María Donati, J.E. Akin
article en
1 citations

Abstract

Additively manufactured, custom-made implants used for reconstruction are a promising treatment following tumor resection. However, failure rates due to mechanical factors remain high when used in the pelvis for even state-of-the-art prosthesis designs. In a collaborative effort between a clinical and an engineering research team, this study evaluated whether patient-specific biomechanical modeling could predict, in a blinded fashion, the mode and location of a clinically-observed mechanical failure. Multiple failure criteria were considered including the risk of bone fracture due to overloading or stress shielding and prosthesis fracture due to overloading or fatigue. The blinded predictions indicated that the risk of fatigue failure in the pubic screws were eight times higher than the most critical ilium screw and two times higher than the most critical cancellous screw. Simulation of stress-shielding during walking matched evidence of osteolysis in the ilium and pubis. Incorporating patient-specific modeling into the custom implant design process may lead to improved durability.

Medical Engineering & PhysicsVol. 138(1)
Istituto Ortopedico Rizzoli (IT), Rice University (US)
Cancer Prevention and Research Institute of Texas
Gender equality
Openalex Percentile: Top 18%
Orthopaedic implants and arthroplasty
2.01
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.