Recoverable degradation of FAPbBr3 perovskite solar cells under reverse-bias: A combined electro-optical investigation

Reverse-bias stability in PV devices is critical to guarantee adequate reliability during sporadic shading instances or when deliberately applying reverse-bias in photodetection applications. Testing reverse-bias stability on PSCs is crucial in providing characterizing insights both into the current state and performance of such devices and also towards their iterative improvement. This paper describes reverse-bias stability testing of semi-transparent FAPbBr 3 perovskite solar cells. Stability against reverse-bias was extensively evaluated through both reverse-bias step-stress (RBSS) tests and constant-bias stress (CBS) tests at different voltage bias intensities. During a series of 10 ks tests, cells were revealed to be stable when operated down to −1.5 V (corresponding to approximately 20 % of the breakdown voltage threshold), whereas at −3 V the observed degradation mainly consists in a decrease in open-circuit voltage (from ∼1.5 ÷ 1.6 V to as low as 0.3 V) and parallel resistance (from ∼10 8 Ω to as low as ∼10 2 Ω), occurring after ∼100 s; a complete recovery is observed, if cells are left in resting conditions after removing the reverse-bias. The observed degradation is ascribed to a temporary shunt-like mechanism, triggered by ion and vacancy displacement and relocation, which causes a drastic energy-band distortion and internal potential compensation. Additional open-circuit voltage decay (OCVD) testing before and after stress reinforces this hypothesis. Reverse-bias step-stress testing until failure confirms that the mechanism occurs across the whole cell, leading to reverse-current magnitudes of over 300 mA/cm 2 . • Reverse-bias on Perovskite Solar Cells can cause temporary/reversible degradation. • Degradation is caused by ionic dynamics and mainly affects open-circuit voltage. • Reverse-bias intensity and duration determine degradation occurrence and extent. • Degradation is non-localized, affecting the entire surface area of the cell. • Recovery occurs by leaving the cell in dark and open-circuit conditions.

Authors

Institutions

Publication Details

Journal
Solar Energy Materials and Solar Cells
Published
2025-03-08
DOI
https://doi.org/10.1016/j.solmat.2025.113547
Citations
3
Primary Topic
Perovskite Materials and Applications
Type
article
Field-Weighted Citation Impact
2.19
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Recoverable degradation of FAPbBr3 perovskite solar cells under reverse-bias: A combined electro-optical investigation

Enrico Zanoni, Aldo Di Carlo, Nicola Trivellin, Matteo Buffolo et al.
3 citations
Solar Energy Materials and Solar Cells
Perovskite Materials and Applications
2.19
article

Recoverable degradation of FAPbBr3 perovskite solar cells under reverse-bias: A combined electro-optical investigation

Enrico Zanoni, Aldo Di Carlo, Nicola Trivellin, Matteo Buffolo, Alessandro Caria, Noah Tormena, Andrea Cester, Matteo Meneghini, Carlo De Santi, Fabio Matteocci, Gaudenzio Meneghesso
article en
3 citations

Abstract

Reverse-bias stability in PV devices is critical to guarantee adequate reliability during sporadic shading instances or when deliberately applying reverse-bias in photodetection applications. Testing reverse-bias stability on PSCs is crucial in providing characterizing insights both into the current state and performance of such devices and also towards their iterative improvement. This paper describes reverse-bias stability testing of semi-transparent FAPbBr 3 perovskite solar cells. Stability against reverse-bias was extensively evaluated through both reverse-bias step-stress (RBSS) tests and constant-bias stress (CBS) tests at different voltage bias intensities. During a series of 10 ks tests, cells were revealed to be stable when operated down to −1.5 V (corresponding to approximately 20 % of the breakdown voltage threshold), whereas at −3 V the observed degradation mainly consists in a decrease in open-circuit voltage (from ∼1.5 ÷ 1.6 V to as low as 0.3 V) and parallel resistance (from ∼10 8 Ω to as low as ∼10 2 Ω), occurring after ∼100 s; a complete recovery is observed, if cells are left in resting conditions after removing the reverse-bias. The observed degradation is ascribed to a temporary shunt-like mechanism, triggered by ion and vacancy displacement and relocation, which causes a drastic energy-band distortion and internal potential compensation. Additional open-circuit voltage decay (OCVD) testing before and after stress reinforces this hypothesis. Reverse-bias step-stress testing until failure confirms that the mechanism occurs across the whole cell, leading to reverse-current magnitudes of over 300 mA/cm 2 . • Reverse-bias on Perovskite Solar Cells can cause temporary/reversible degradation. • Degradation is caused by ionic dynamics and mainly affects open-circuit voltage. • Reverse-bias intensity and duration determine degradation occurrence and extent. • Degradation is non-localized, affecting the entire surface area of the cell. • Recovery occurs by leaving the cell in dark and open-circuit conditions.

Solar Energy Materials and Solar CellsVol. 285
University of Rome Tor Vergata (IT), University of Padua (IT), Istituto Nazionale di Fisica Nucleare, Sezione di Padova (IT), Institute of Structure of Matter (IT), R2M Solution (Italy) (IT), Osservatorio Astronomico di Padova (IT)
Openalex Percentile: Top 13%
Perovskite Materials and Applications
2.19
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.