Robust Fetal Head Circumference Calculation on Ultrasound Images Using Just-in-Time Compiled Ellipse Fitting

Calculation of fetal head circumference (HC) is essential for various purposes, particularly in evaluating fetal health during prenatal care. However, performing HC calculations manually is labor intensive, prone to errors, and requires specific expertise. Thus, there is a pressing demand for automated methods for HC calculation. Recent automation methods for head circumference calculation focus on using deep learning that is often slow and memory hog due to the high computational complexity. This study presents a novel approach for fast and efficient automatic HC calculation from 2D ultrasound images by leveraging just-in-time compiled ellipse fitting based on Randomized Hough Transform. Before ellipse fitting, there are downscaling, blurring, and clean edge detection to increase robustness. After ellipse fitting, there is circumference calculation using the Ramanujan approximation. Our approach achieved a remarkable speed of 0.41 s per image with less than 800 kB of memory. It demonstrated robust accuracy with a Hausdorff distance of 3.88 mm, a Dice score of 0.93, and an absolute difference of 7.24 mm, which is comparable to existing methods.

Authors

Institutions

Publication Details

Published
2024-12-01
DOI
https://doi.org/10.1109/tencon61640.2024.10903012
Primary Topic
Image and Object Detection Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Robust Fetal Head Circumference Calculation on Ultrasound Images Using Just-in-Time Compiled Ellipse Fitting

Achmad Solaeman, Fhareza Alvindo, Pandega Abyan Zumarsyah
Image and Object Detection Techniques
article

Robust Fetal Head Circumference Calculation on Ultrasound Images Using Just-in-Time Compiled Ellipse Fitting

Achmad Solaeman, Fhareza Alvindo, Pandega Abyan Zumarsyah
article en

Abstract

Calculation of fetal head circumference (HC) is essential for various purposes, particularly in evaluating fetal health during prenatal care. However, performing HC calculations manually is labor intensive, prone to errors, and requires specific expertise. Thus, there is a pressing demand for automated methods for HC calculation. Recent automation methods for head circumference calculation focus on using deep learning that is often slow and memory hog due to the high computational complexity. This study presents a novel approach for fast and efficient automatic HC calculation from 2D ultrasound images by leveraging just-in-time compiled ellipse fitting based on Randomized Hough Transform. Before ellipse fitting, there are downscaling, blurring, and clean edge detection to increase robustness. After ellipse fitting, there is circumference calculation using the Ramanujan approximation. Our approach achieved a remarkable speed of 0.41 s per image with less than 800 kB of memory. It demonstrated robust accuracy with a Hausdorff distance of 3.88 mm, a Dice score of 0.93, and an absolute difference of 7.24 mm, which is comparable to existing methods.

Universitas Gadjah Mada (ID)
Openalex Percentile: Top 72%
Image and Object Detection Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Robust Fetal Head Circumference Calculation on Ultrasound Images Using Just-in-Time Compiled Ellipse Fitting — Achmad Solaeman, Fhareza Alvindo, et al. · (2024) | TGRS Research Map | TGRS