Detection of Series Arc Faults in Photovoltaic System Based on Wavelet Filter Evaluation

Series Arc Faults (SAFs) in PV systems are very difficult to detect owing to inverter noise. Therefore, this study aims to detect SAFs by evaluating data collected from three different measurement: current measurement, voltage measurement on the arc fault generator, and PV voltage measurement with three different case studies based on the amount of Photovoltaic (PV) voltage from the Direct Current Power Supply (DCPS) that can simulate real PV conditions. Three wavelet filter types, such as Haar, Daubechies 4 (db4), and Biortogonal 3.1 (3.1) with a decomposition level of 15. The findings of this research indicate that the PV voltage is capable of measuring SAFs with evaluating wavelet filter. In addition, the arcing power in the steady state increased as the PV source voltage increased. The threshold limits for normal conditions can be established using the Haar wavelet filter method and db4 detail coefficient value. However, it is not recommended to utilize the Bior 3.1 method for detecting SAFs in PV systems because of the high inverter noise during normal conditions in some cases. The contribution of this study is that detection using the PV voltage can be performed for arcing detection with wavelet filter evaluation.

Authors

Institutions

Publication Details

Published
2024-12-01
DOI
https://doi.org/10.1109/tencon61640.2024.10903081
Primary Topic
Electrical Fault Detection and Protection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Detection of Series Arc Faults in Photovoltaic System Based on Wavelet Filter Evaluation

Dimas Anton Asfani, I Made Yulistya Negara, Daniar Fahmi, Ibrahim Sefik et al.
Electrical Fault Detection and Protection
article

Detection of Series Arc Faults in Photovoltaic System Based on Wavelet Filter Evaluation

Dimas Anton Asfani, I Made Yulistya Negara, Daniar Fahmi, Ibrahim Sefik, Arief Budi Ksatria, Bagus Septianto, Adams Tryas Alfian
article en

Abstract

Series Arc Faults (SAFs) in PV systems are very difficult to detect owing to inverter noise. Therefore, this study aims to detect SAFs by evaluating data collected from three different measurement: current measurement, voltage measurement on the arc fault generator, and PV voltage measurement with three different case studies based on the amount of Photovoltaic (PV) voltage from the Direct Current Power Supply (DCPS) that can simulate real PV conditions. Three wavelet filter types, such as Haar, Daubechies 4 (db4), and Biortogonal 3.1 (3.1) with a decomposition level of 15. The findings of this research indicate that the PV voltage is capable of measuring SAFs with evaluating wavelet filter. In addition, the arcing power in the steady state increased as the PV source voltage increased. The threshold limits for normal conditions can be established using the Haar wavelet filter method and db4 detail coefficient value. However, it is not recommended to utilize the Bior 3.1 method for detecting SAFs in PV systems because of the high inverter noise during normal conditions in some cases. The contribution of this study is that detection using the PV voltage can be performed for arcing detection with wavelet filter evaluation.

Sepuluh Nopember Institute of Technology (ID), Hamburg University of Technology (DE)
Affordable and clean energy
Openalex Percentile: Top 74%
Electrical Fault Detection and Protection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.