Enhanced Optimal Control of a Magnetically Actuated Capsule Endoscope Using Electromagnetic Coils Considering Small Intestine Dynamics

Active locomotion of capsule endoscopes has become a prominent progress in minimally invasive diagnostic procedures. Utilizing external magnetic fields for this purpose enables contactless actuation and enhanced maneuverability. This study presents an optimal control technique for magnetically actuated capsule endoscopes (MACE) within the small intestine, using a modified OCTAMAG setup. The objective is to minimize input currents while ensuring accurate path tracking, thereby preventing coil overheating and avoiding actuation inaccuracies. A correction force is also incorporated into the controller to stabilize it against external disturbances. The proposed method is evaluated using a path inspired by the small intestine and compared to conventional PID control. Results show that the optimal controller achieves superior path tracking while maintaining input currents within safe limits. Additionally, the disturbance rejection capabilities of the optimal controller are comparable to those of the PID.

Authors

Institutions

Publication Details

Published
2024-12-17
DOI
https://doi.org/10.1109/icrom64545.2024.10903534
Primary Topic
Micro and Nano Robotics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Enhanced Optimal Control of a Magnetically Actuated Capsule Endoscope Using Electromagnetic Coils Considering Small Intestine Dynamics

Hossein Nejat Pishkenari, Mirmosadegh Jamali, Mohammadreza Zarifi Khameneh, Mohammadhossein Sarkhosh
Micro and Nano Robotics
article

Enhanced Optimal Control of a Magnetically Actuated Capsule Endoscope Using Electromagnetic Coils Considering Small Intestine Dynamics

Hossein Nejat Pishkenari, Mirmosadegh Jamali, Mohammadreza Zarifi Khameneh, Mohammadhossein Sarkhosh
article en

Abstract

Active locomotion of capsule endoscopes has become a prominent progress in minimally invasive diagnostic procedures. Utilizing external magnetic fields for this purpose enables contactless actuation and enhanced maneuverability. This study presents an optimal control technique for magnetically actuated capsule endoscopes (MACE) within the small intestine, using a modified OCTAMAG setup. The objective is to minimize input currents while ensuring accurate path tracking, thereby preventing coil overheating and avoiding actuation inaccuracies. A correction force is also incorporated into the controller to stabilize it against external disturbances. The proposed method is evaluated using a path inspired by the small intestine and compared to conventional PID control. Results show that the optimal controller achieves superior path tracking while maintaining input currents within safe limits. Additionally, the disturbance rejection capabilities of the optimal controller are comparable to those of the PID.

Sharif University of Technology (IR)
Openalex Percentile: Top 83%
Micro and Nano Robotics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.