Design of Control System for Adult Ventilator

This study describes the development of a control system for a low-cost ventilator prototype for adults. A prototype was developed based on the existing infant ventilator. Flow meters and another solenoid valve were integrated into the design to satisfy adult patients' requirements. Other components, such as PLC, HMI, LED light, buzzer, and throttling valves, were used. 3D printed parts were also developed for particular components that are not available off the shelf. Alarms were also incorporated in the system design. The ventilator was tested in different ventilator settings. Results show that the minimum requirement for an Emergency Use Ventilator (EUV) was satisfied. The range of Tidal Volume is 100mL to 650mL and 5cmH2O to 17 cmH2O for PEEP. For Tidal Volume, PEEP and PIP measurements, the values fall within the acceptable tolerances: ± 50mL or ±10% of measured value for Tidal Volume and ±2.5 cmH2O for PEEP and PIP. This study covers only the design and development, functional and stress testing. Clinical test will be conducted in separate study.

Authors

Publication Details

Published
2024-12-01
DOI
https://doi.org/10.1109/tencon61640.2024.10902735
Primary Topic
IoT-based Smart Home Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Design of Control System for Adult Ventilator

Franz Joseph D. Libao, Godfreyson J. Nardo, Glen D. Espeña
IoT-based Smart Home Systems
article

Design of Control System for Adult Ventilator

Franz Joseph D. Libao, Godfreyson J. Nardo, Glen D. Espeña
article en

Abstract

This study describes the development of a control system for a low-cost ventilator prototype for adults. A prototype was developed based on the existing infant ventilator. Flow meters and another solenoid valve were integrated into the design to satisfy adult patients' requirements. Other components, such as PLC, HMI, LED light, buzzer, and throttling valves, were used. 3D printed parts were also developed for particular components that are not available off the shelf. Alarms were also incorporated in the system design. The ventilator was tested in different ventilator settings. Results show that the minimum requirement for an Emergency Use Ventilator (EUV) was satisfied. The range of Tidal Volume is 100mL to 650mL and 5cmH2O to 17 cmH2O for PEEP. For Tidal Volume, PEEP and PIP measurements, the values fall within the acceptable tolerances: ± 50mL or ±10% of measured value for Tidal Volume and ±2.5 cmH2O for PEEP and PIP. This study covers only the design and development, functional and stress testing. Clinical test will be conducted in separate study.

Affordable and clean energy
Openalex Percentile: Top 74%
IoT-based Smart Home Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Design of Control System for Adult Ventilator — Franz Joseph D. Libao, Godfreyson J. Nardo, et al. · (2024) | TGRS Research Map | TGRS