Mitigation of Noise on Surface Electromyography (sEMG) Signals through Signal Filtering Algorithms

Surface electromyography (sEMG) is crucial in sports science, offering insights into muscle activation patterns. However, standard devices like the Delsys Trigno Wireless System are relatively costly. This study presents a prototype that simultaneously obtains sEMG and IMU signals to measure muscle activity. The presence of noise necessitates signal processing techniques to be applied to the raw signal, including feed-forward comb, adaptive, and wavelet filters. Evaluation against a reference signal revealed that the wavelet filter performed best, exhibiting the lowest MSE and highest SNR scores. Specifically, it achieved MSE scores of 2.62E-10 in the time domain, 6.25E-22 in PSD, and SNR scores 13.96 for squats. These findings underscore the effectiveness of the wavelet filter in reducing sEMG signal noise.

Authors

Institutions

Publication Details

Published
2024-12-01
DOI
https://doi.org/10.1109/tencon61640.2024.10902985
Citations
2
Primary Topic
Muscle activation and electromyography studies
Type
article
Field-Weighted Citation Impact
0.37
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Mitigation of Noise on Surface Electromyography (sEMG) Signals through Signal Filtering Algorithms

Jehiel D. Santos, Jose M. Sandoval, Justine B. Duran, Ma. Madecheen S. Pangaliman et al.
2 citations
Muscle activation and electromyography studies
0.37
article

Mitigation of Noise on Surface Electromyography (sEMG) Signals through Signal Filtering Algorithms

Jehiel D. Santos, Jose M. Sandoval, Justine B. Duran, Ma. Madecheen S. Pangaliman, Angelito A. Silverio, Seigfred V. Prado, Consuelo Gonzalez-Suarez, Reil Vinard Espino, Jazzmine Gale Flores, Elaine Nicole S. Bulseco, Denisse V. Cunanan, Ma. Belinda C. Fidel, Regina Rose B. Magpantay, James Andrew M. Roxas, Akira Ryodji P. Tagura
article en
2 citations

Abstract

Surface electromyography (sEMG) is crucial in sports science, offering insights into muscle activation patterns. However, standard devices like the Delsys Trigno Wireless System are relatively costly. This study presents a prototype that simultaneously obtains sEMG and IMU signals to measure muscle activity. The presence of noise necessitates signal processing techniques to be applied to the raw signal, including feed-forward comb, adaptive, and wavelet filters. Evaluation against a reference signal revealed that the wavelet filter performed best, exhibiting the lowest MSE and highest SNR scores. Specifically, it achieved MSE scores of 2.62E-10 in the time domain, 6.25E-22 in PSD, and SNR scores 13.96 for squats. These findings underscore the effectiveness of the wavelet filter in reducing sEMG signal noise.

University of Santo Tomas (PH)
Climate action
Openalex Percentile: Top 41%
Muscle activation and electromyography studies
0.37
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.