Extraction of Heart Rate from Photoplethysmography Signals on Multiple Sites for Wearable Heart Monitoring Systems

This study contributes to improving heart rate (HR) monitoring by comparing the Peripheral Beat Amplitude (PBA) and Smoothed Z-score Peak Detection (Z-Score) algorithms for HR extraction across different body sites. The Z-Score algorithm, leveraging on edge computing, demonstrated higher accuracy than PBA, with a Mean Absolute Error (MAE) around 4 BPM. The study also explores the suitability of the Perfusion Ratio technique for Blood Oxygen (SpO<inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</inf>) levels and the Welch method for respiratory rate (RR). Testing was conducted simultaneously at four distinct body sites (finger, wrist, arm, and ankle) during sitting and walking activities on six healthy individuals. Results indicate that the wrist is the optimal measurement site for various physiological parameters. Post-processing techniques were deliberately chosen to enhance the system's overall performance. The focus on HR necessitated evaluating two algorithms, given its critical importance. For SpO<inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</inf> and RR, single algorithms were selected to streamline processing while ensuring reliable measurements. The developed system exhibits acceptable power consumption of 51.98 m W and achieves an average coverage of 80% in controlled tests, indicating a significant portion of monitoring time provides accurate physiological data. This study emphasizes the deliberate selection of algorithms and measurement sites, demonstrating the superiority of the Z-Score algorithm and the practicality of integrating HR, SpO<inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</inf>, RR, and PPG monitoring in a single system.

Authors

Institutions

Publication Details

Published
2024-12-01
DOI
https://doi.org/10.1109/tencon61640.2024.10902829
Citations
1
Primary Topic
Non-Invasive Vital Sign Monitoring
Type
article
Field-Weighted Citation Impact
0.18
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Extraction of Heart Rate from Photoplethysmography Signals on Multiple Sites for Wearable Heart Monitoring Systems

Carl Timothy Tolentino, Paul Jason Co, John Richard E. Hizon, Marc Rosales et al.
1 citations
Non-Invasive Vital Sign Monitoring
0.18
article

Extraction of Heart Rate from Photoplethysmography Signals on Multiple Sites for Wearable Heart Monitoring Systems

Carl Timothy Tolentino, Paul Jason Co, John Richard E. Hizon, Marc Rosales, Ghessette Mae Punay, Reynaldo Guieb
article en
1 citations

Abstract

This study contributes to improving heart rate (HR) monitoring by comparing the Peripheral Beat Amplitude (PBA) and Smoothed Z-score Peak Detection (Z-Score) algorithms for HR extraction across different body sites. The Z-Score algorithm, leveraging on edge computing, demonstrated higher accuracy than PBA, with a Mean Absolute Error (MAE) around 4 BPM. The study also explores the suitability of the Perfusion Ratio technique for Blood Oxygen (SpO<inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</inf>) levels and the Welch method for respiratory rate (RR). Testing was conducted simultaneously at four distinct body sites (finger, wrist, arm, and ankle) during sitting and walking activities on six healthy individuals. Results indicate that the wrist is the optimal measurement site for various physiological parameters. Post-processing techniques were deliberately chosen to enhance the system's overall performance. The focus on HR necessitated evaluating two algorithms, given its critical importance. For SpO<inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</inf> and RR, single algorithms were selected to streamline processing while ensuring reliable measurements. The developed system exhibits acceptable power consumption of 51.98 m W and achieves an average coverage of 80% in controlled tests, indicating a significant portion of monitoring time provides accurate physiological data. This study emphasizes the deliberate selection of algorithms and measurement sites, demonstrating the superiority of the Z-Score algorithm and the practicality of integrating HR, SpO<inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</inf>, RR, and PPG monitoring in a single system.

University of the Philippines Diliman (PH)
Openalex Percentile: Top 49%
Non-Invasive Vital Sign Monitoring
0.18
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Extraction of Heart Rate from Photoplethysmography Signals on Multiple Sites for Wearable Heart Monitoring Systems — Carl Timothy Tolentino, Paul Jason Co, et al. · (2024) | TGRS Research Map | TGRS