Shorter pre-data acquisition time for magnetic particle imaging using AC susceptometry

Magnetic nanoparticle imaging (MPI) with a detection coil array can be used to estimate the position and quantity of magnetic nanoparticles (MNPs) via inverse problem analysis. In MPI studies, a system matrix is experimentally acquired for inverse problem analysis. However, a long acquisition time causes large temperature fluctuations in the excitation coil and electric circuit, and drift noise is present in the system matrix. In this study, we propose the generation of a system matrix by fitting a simulated system matrix using AC susceptometry to fewer experimental measurement points. Even when an inverse problem analysis was performed using a system matrix fitted with 1/100th the number of measurement data, the accuracy was higher than that obtained using an experimental matrix. This contributed to shortening the acquisition time.

Authors

Institutions

Publication Details

Journal
AIP Advances
Published
2025-03-01
DOI
https://doi.org/10.1063/9.0000865
Primary Topic
Characterization and Applications of Magnetic Nanoparticles
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Shorter pre-data acquisition time for magnetic particle imaging using AC susceptometry

Takashi Yoshida, Teruyoshi Sasayama, Naoya Futagawa
AIP Advances
Characterization and Applications of Magnetic Nanoparticles
article

Shorter pre-data acquisition time for magnetic particle imaging using AC susceptometry

Takashi Yoshida, Teruyoshi Sasayama, Naoya Futagawa
article en

Abstract

Magnetic nanoparticle imaging (MPI) with a detection coil array can be used to estimate the position and quantity of magnetic nanoparticles (MNPs) via inverse problem analysis. In MPI studies, a system matrix is experimentally acquired for inverse problem analysis. However, a long acquisition time causes large temperature fluctuations in the excitation coil and electric circuit, and drift noise is present in the system matrix. In this study, we propose the generation of a system matrix by fitting a simulated system matrix using AC susceptometry to fewer experimental measurement points. Even when an inverse problem analysis was performed using a system matrix fitted with 1/100th the number of measurement data, the accuracy was higher than that obtained using an experimental matrix. This contributed to shortening the acquisition time.

AIP AdvancesVol. 15(3)
Kyushu University (JP)
Japan Society for the Promotion of Science
Affordable and clean energy
Openalex Percentile: Top 96%
Characterization and Applications of Magnetic Nanoparticles
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Shorter pre-data acquisition time for magnetic particle imaging using AC susceptometry — Takashi Yoshida, Teruyoshi Sasayama, et al. · AIP Advances (2025) | TGRS Research Map | TGRS