The DELIVER Technique

The delivery of the rotational atherectomy burr can sometimes be hindered in distal calcified lesions complicated by proximal vessel tortuosity or other obstacles. This problem may result in procedural failure or fatal complications, including coronary perforation, burr entrapment, or driveshaft fracture. To prevent these catastrophic outcomes and ensure successful burr delivery, we introduce the DELIVER (Deep Engagement of guide catheter or 5-F chiLd-guIde catheter for burr deliVEry and subsequent Rotational atherectomy) technique. This method involves deep catheter insertion beyond proximal vessel tortuosity or other obstacles, using strategies such as the distal balloon anchoring technique. Once the catheter is positioned, the rotational atherectomy burr is advanced through it to facilitate the atherectomy of the distal target lesion. This report presents 3 cases where the DELIVER technique was applied successfully to treat distal lesions. The technique enabled smooth and atraumatic burr delivery, even through tortuous arterial segments or other challenging anatomical structures.

Authors

Institutions

Publication Details

Journal
JACC Case Reports
Published
2025-03-01
DOI
https://doi.org/10.1016/j.jaccas.2024.103177
Citations
2
Primary Topic
Cardiac Valve Diseases and Treatments
Type
article
Field-Weighted Citation Impact
2.78
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The DELIVER Technique

Katsuhiko Sato, Shoichi Kuramitsu, Takuro Sugie, Yoshifumi Kashima et al.
2 citations
JACC Case Reports
Cardiac Valve Diseases and Treatments
2.78
article

The DELIVER Technique

Katsuhiko Sato, Shoichi Kuramitsu, Takuro Sugie, Yoshifumi Kashima, Daitaro Kanno, Yutaka Tadano, Tsutomu Fujita, Umihiko Kaneko, Ken Kobayashi
article en
2 citations

Abstract

The delivery of the rotational atherectomy burr can sometimes be hindered in distal calcified lesions complicated by proximal vessel tortuosity or other obstacles. This problem may result in procedural failure or fatal complications, including coronary perforation, burr entrapment, or driveshaft fracture. To prevent these catastrophic outcomes and ensure successful burr delivery, we introduce the DELIVER (Deep Engagement of guide catheter or 5-F chiLd-guIde catheter for burr deliVEry and subsequent Rotational atherectomy) technique. This method involves deep catheter insertion beyond proximal vessel tortuosity or other obstacles, using strategies such as the distal balloon anchoring technique. Once the catheter is positioned, the rotational atherectomy burr is advanced through it to facilitate the atherectomy of the distal target lesion. This report presents 3 cases where the DELIVER technique was applied successfully to treat distal lesions. The technique enabled smooth and atraumatic burr delivery, even through tortuous arterial segments or other challenging anatomical structures.

JACC Case ReportsVol. 30(5)
Sapporo Science Center (JP)
Openalex Percentile: Top 11%
Cardiac Valve Diseases and Treatments
2.78
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

The DELIVER Technique — Katsuhiko Sato, Shoichi Kuramitsu, et al. · JACC Case Reports (2025) | TGRS Research Map | TGRS