Fire response of steel frames retrofitted against progressive collapse

A large share of the existing building stock was built before the implementation of design standards against progressive collapse and is in need for retrofitting. Retrofit measures are typically designed with a threat-independent approach, involving the removal of one or more structural elements . This approach has been widely applied to deal with events such as impacts or blasts (short-duration events), but may not be adequate for fire scenarios (long-duration events) due to peculiar phenomena such as restrained thermal expansion and degradation of mechanical properties. This is particularly relevant for steel structures, which are sensitive to thermal attack and are typically designed as low-redundant systems, and used in large industrial or strategic buildings. This paper investigates the fire response of a 9-storey steel moment-resisting frame before and after progressive collapse retrofitting. Three retrofit measures designed considering the removal of the central ground storey column are investigated, including a bracing system, a roof-truss, and the concrete encasement of critical columns. Parametric fires, different compartment scenarios, and various loading levels are considered. The retrofit measures are shown to improve the fire response of the structure by preventing or delaying collapse. Finally, the effectiveness and suitability of the measures in different circumstances are discussed. • Retrofit measures against column loss scenarios enhance the MRF’s fire performance • Collapse for simultaneous loss of capacity of heated and adjacent buckled columns • Bracing and roof-truss systems help delay or prevent structural collapse • Column encasement ensures fire protection, preventing collapse

Authors

Institutions

Publication Details

Journal
Fire Safety Journal
Published
2025-03-08
DOI
https://doi.org/10.1016/j.firesaf.2025.104371
Citations
3
Primary Topic
Structural Response to Dynamic Loads
Type
article
Field-Weighted Citation Impact
2.86
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Fire response of steel frames retrofitted against progressive collapse

Fabio Freddi, Luca Possidente, Nicola Tondini
3 citations
Fire Safety Journal
Structural Response to Dynamic Loads
2.86
article

Fire response of steel frames retrofitted against progressive collapse

Fabio Freddi, Luca Possidente, Nicola Tondini
article en
3 citations

Abstract

A large share of the existing building stock was built before the implementation of design standards against progressive collapse and is in need for retrofitting. Retrofit measures are typically designed with a threat-independent approach, involving the removal of one or more structural elements . This approach has been widely applied to deal with events such as impacts or blasts (short-duration events), but may not be adequate for fire scenarios (long-duration events) due to peculiar phenomena such as restrained thermal expansion and degradation of mechanical properties. This is particularly relevant for steel structures, which are sensitive to thermal attack and are typically designed as low-redundant systems, and used in large industrial or strategic buildings. This paper investigates the fire response of a 9-storey steel moment-resisting frame before and after progressive collapse retrofitting. Three retrofit measures designed considering the removal of the central ground storey column are investigated, including a bracing system, a roof-truss, and the concrete encasement of critical columns. Parametric fires, different compartment scenarios, and various loading levels are considered. The retrofit measures are shown to improve the fire response of the structure by preventing or delaying collapse. Finally, the effectiveness and suitability of the measures in different circumstances are discussed. • Retrofit measures against column loss scenarios enhance the MRF’s fire performance • Collapse for simultaneous loss of capacity of heated and adjacent buckled columns • Bracing and roof-truss systems help delay or prevent structural collapse • Column encasement ensures fire protection, preventing collapse

Fire Safety JournalVol. 153
University of Trento (IT), University College London (GB)
Sustainable cities and communities
Openalex Percentile: Top 11%
Structural Response to Dynamic Loads
2.86
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Fire response of steel frames retrofitted against progressive collapse — Fabio Freddi, Luca Possidente, et al. · Fire Safety Journal (2025) | TGRS Research Map | TGRS