Studies and development of FBG based multi-point temperature sensor for vacuum chambers of synchrotron radiation source Indus-2
This paper presents the development and deployment of a multi-point fiber Bragg grating (FBG) sensor system for precise temperature monitoring along the vacuum chamber walls of dipole and Pinger magnets in Indus-2, a synchrotron radiation source. The challenging environment includes bremsstrahlung radiation (20 Rad/h), strong magnetic fields (1.5 T), and high RF fields (∼0.8 MV/m at 505.812 MHz). The sensor system was created by inscribing multiple FBGs at distinct wavelengths on a single optical fiber using the second harmonic of a copper vapor laser (CVL). The FBG array was validated for operation in high-radiation and high-voltage (∼10 kV) conditions. It was installed to monitor temperature profiles during Indus-2 operation at 2.5 GeV, 200 mA, where chamber temperatures ranged from 18 °C to 40 °C. The significance of this observation lies in its potential application for the early detection of electron beam orbit mis-steering occurrences, thereby facilitating real-time temperature monitoring and the subsequent optimization of electron beam orbit alignment. Such proactive measures are crucial for ensuring the dependable and consistent operation of Indus-2.
Authors
- S. Barath Kumar
- B. K. Sindal
- Jitendra Kumar
- Dhiraj Yadav (ORCID: https://orcid.org/0000-0002-1183-695X)
- Manoj Saxena (ORCID: https://orcid.org/0000-0002-9368-4194)
- K. V. A. N. P. S. Kumar (ORCID: https://orcid.org/0009-0006-0778-038X)
- R. Mahakud (ORCID: https://orcid.org/0000-0002-5432-6271)
- Praveen Agrawal (ORCID: https://orcid.org/0000-0002-8892-9169)
- Om Prakash (ORCID: https://orcid.org/0000-0002-5918-6554)
Institutions
- Raja Ramanna Centre for Advanced Technology (IN)
- Homi Bhabha National Institute (IN)
Publication Details
- Journal
- Results in Optics
- Published
- 2025-03-08
- DOI
- https://doi.org/10.1016/j.rio.2025.100805
- Citations
- 3
- Primary Topic
- Advanced Fiber Optic Sensors
- Type
- article
- Field-Weighted Citation Impact
- 2.19