Thermofluid-dynamic assessment of the dual cooling scheme EU-DEMO divertor cassette

The EU-DEMO divertor is currently foreseen to employ a dual cooling scheme, which involves two separate cooling circuits for the Cassette Body (CB) and the Vertical Targets (VTs), provided with cooling water at distinct operating conditions. Following the EU-DEMO project Gate Review 1, the cassette design has been revised to employ a high-temperature (295-328 °C) and high-pressure (15.5 MPa) coolant for the CB cooling circuit. These design assumptions present novel challenges in achieving uniform and effective cooling of the structure, to ensure reliable operation over the intended lifetime. Furthermore, alternative materials for the VTs-supporting Target Support Bodies (TSBs), namely CuCrZr, SS 316Ti and Eurofer97, are currently being evaluated to extend the operational lifetime of these components under irradiation. The University of Palermo, in collaboration with EUROfusion and ENEA, analysed the steady-state thermal-hydraulic performance of the EU-DEMO divertor cooling circuits with an integrated conjugate heat transfer analysis campaign of the entire divertor cassette, with the twofold aim to evaluate the CB thermal performance under the revised coolant conditions and to compare the temperature distribution in the TSBs with the different materials considered. The work was carried out following a numerical approach based on the finite volume method and adopting the ANSYS CFX computational fluid-dynamic commercial code. Models, loads and boundary conditions are herewith reported and critically discussed, together with the main outcomes obtained. • The cooling performances of a DEMO dual cooling divertor are investigated. • PWR-like coolant operating conditions are adopted for the cassette cooling circuit. • The VTs connected in series require a higher coolant pressure for their circuit. • Thermal hot spots and CHF issues are found in the cassette, needing design revision. • Simulation of the entire cassette required to predict the VT support temperature.

Authors

Institutions

Publication Details

Journal
Fusion Engineering and Design
Published
2025-03-05
DOI
https://doi.org/10.1016/j.fusengdes.2025.114903
Citations
3
Primary Topic
Magnetic confinement fusion research
Type
article
Field-Weighted Citation Impact
5.61

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Thermofluid-dynamic assessment of the dual cooling scheme EU-DEMO divertor cassette

R. Burlon, Elio Angelo Tomarchio, G. Mazzone, A. Quartararo et al.
3 citations
Fusion Engineering and Design
Magnetic confinement fusion research
5.61
article

Thermofluid-dynamic assessment of the dual cooling scheme EU-DEMO divertor cassette

R. Burlon, Elio Angelo Tomarchio, G. Mazzone, A. Quartararo, P. Chiovaro, F.M. Castrovinci, E. Vallone, G. Bongiovì, S. Vacca, S. Basile, Alberto Gioè, P.A. Di Maio, J.-H. You, Sofia Maggio
article en
3 citations

Abstract

The EU-DEMO divertor is currently foreseen to employ a dual cooling scheme, which involves two separate cooling circuits for the Cassette Body (CB) and the Vertical Targets (VTs), provided with cooling water at distinct operating conditions. Following the EU-DEMO project Gate Review 1, the cassette design has been revised to employ a high-temperature (295-328 °C) and high-pressure (15.5 MPa) coolant for the CB cooling circuit. These design assumptions present novel challenges in achieving uniform and effective cooling of the structure, to ensure reliable operation over the intended lifetime. Furthermore, alternative materials for the VTs-supporting Target Support Bodies (TSBs), namely CuCrZr, SS 316Ti and Eurofer97, are currently being evaluated to extend the operational lifetime of these components under irradiation. The University of Palermo, in collaboration with EUROfusion and ENEA, analysed the steady-state thermal-hydraulic performance of the EU-DEMO divertor cooling circuits with an integrated conjugate heat transfer analysis campaign of the entire divertor cassette, with the twofold aim to evaluate the CB thermal performance under the revised coolant conditions and to compare the temperature distribution in the TSBs with the different materials considered. The work was carried out following a numerical approach based on the finite volume method and adopting the ANSYS CFX computational fluid-dynamic commercial code. Models, loads and boundary conditions are herewith reported and critically discussed, together with the main outcomes obtained. • The cooling performances of a DEMO dual cooling divertor are investigated. • PWR-like coolant operating conditions are adopted for the cassette cooling circuit. • The VTs connected in series require a higher coolant pressure for their circuit. • Thermal hot spots and CHF issues are found in the cassette, needing design revision. • Simulation of the entire cassette required to predict the VT support temperature.

Fusion Engineering and DesignVol. 214
National Agency for New Technologies, Energy and Sustainable Economic Development (IT), Max Planck Institute for Plasma Physics (DE), University of Palermo (IT)
European Commission, Agenzia Nazionale per le Nuove Tecnologie, l'Energia e lo Sviluppo Economico Sostenibile, Euratom Research and Training Programme
Climate action
Openalex Percentile: Top 6%
Magnetic confinement fusion research
5.61
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.