A concept for fully automated segmentation of bone in ultrasound imaging

This study proposes a novel concept for the automated and computerised segmentation of ultrasound images of bone based on motion information. Force is applied on the heel region using the ultrasound probe and then removed while recording the video of the bone using ultrasound. The interface between the bone and surrounding tissues is the region that moves with maximum speed. This concept is utilised to determine a map of movement, where speed is the criterion used for the bone segmentation from the surrounding tissues. To achieve that, the image is subdivided into regions of uniform sizes, followed by tracking individual regions in the successive frames of the video using an optical flow algorithm. The average movement speed is calculated for the regions. Then, the regions with the higher speed are identified as bone surfaces. It is given as the initial contour for the Chan-Vese algorithm to achieve smoother bone surfaces. Then, the final output from the Chan-Vese is post-processed using a boundary tracing algorithm to get the last automated bone segmented output. The segmented outcomes are compared against the manually segmented images from the experts to determine the accuracy. Bhattacharyya distances are used to calculate the accuracy of the algorithmic and manual output. The quantitative results from Bhattacharyya distances indicated an excellent overlap between algorithmic and manual works (average ± STDEV Bhattacharyya distance: 0.06285 ± 0.002051). The bone-segmented output from the optical flow algorithm is compared with the model output and the texture-based segmentation method's output. The work from the motion estimation methods has better segmentation accuracy than the model and texture segmentation methods. The results of this study suggest that this method is the first attempt to segment the heel bone from the ultrasound image using motion information.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2025-03-08
DOI
https://doi.org/10.1038/s41598-025-92380-3
Citations
4
Primary Topic
Medical Image Segmentation Techniques
Type
article
Field-Weighted Citation Impact
5.10

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A concept for fully automated segmentation of bone in ultrasound imaging

Ananth Hari Ramakrishnan, Nachiappan Chockalingam, Rengarajan Amirtharajan, R. Muthaiah et al.
4 citations
Scientific Reports
Medical Image Segmentation Techniques
5.10
article

A concept for fully automated segmentation of bone in ultrasound imaging

Ananth Hari Ramakrishnan, Nachiappan Chockalingam, Rengarajan Amirtharajan, R. Muthaiah, Panagiotis Chatzistergos, Kannan Krithivasan
article en
4 citations

Abstract

This study proposes a novel concept for the automated and computerised segmentation of ultrasound images of bone based on motion information. Force is applied on the heel region using the ultrasound probe and then removed while recording the video of the bone using ultrasound. The interface between the bone and surrounding tissues is the region that moves with maximum speed. This concept is utilised to determine a map of movement, where speed is the criterion used for the bone segmentation from the surrounding tissues. To achieve that, the image is subdivided into regions of uniform sizes, followed by tracking individual regions in the successive frames of the video using an optical flow algorithm. The average movement speed is calculated for the regions. Then, the regions with the higher speed are identified as bone surfaces. It is given as the initial contour for the Chan-Vese algorithm to achieve smoother bone surfaces. Then, the final output from the Chan-Vese is post-processed using a boundary tracing algorithm to get the last automated bone segmented output. The segmented outcomes are compared against the manually segmented images from the experts to determine the accuracy. Bhattacharyya distances are used to calculate the accuracy of the algorithmic and manual output. The quantitative results from Bhattacharyya distances indicated an excellent overlap between algorithmic and manual works (average ± STDEV Bhattacharyya distance: 0.06285 ± 0.002051). The bone-segmented output from the optical flow algorithm is compared with the model output and the texture-based segmentation method's output. The work from the motion estimation methods has better segmentation accuracy than the model and texture segmentation methods. The results of this study suggest that this method is the first attempt to segment the heel bone from the ultrasound image using motion information.

Scientific ReportsVol. 15(1)
University of Dundee (GB), University of Staffordshire (GB), SASTRA University (IN)
UK-India Education and Research Initiative, Department of Science and Technology, Ministry of Science and Technology, India, SASTRA University
Openalex Percentile: Top 5%
Medical Image Segmentation Techniques
5.10
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.