Initial characterization of a novel dual-robot orthovoltage radiotherapy system

<b>Purpose:</b>Adequate access to radiotherapy is a critical global concern affecting low-resource settings such as low- and middle-income countries and rural regions. We propose to reduce this disparity by developing a novel low-cost radiotherapy device that treats using non-coplanar techniques and a 225 kVp x-ray tube.<b>Methods:</b>This novel device has been preliminarily characterized spectrally, via spectrometer measurements, dosimetrically, via percent depth dose curves and 2D profiles, and geometrically, via a coplanar star-shot. Dosimetric and geometric evaluations were then combined by performing a proof of workflow of the KOALA system. Monte Carlo simulations were run in TOPAS to validate dosimetric measurements and the proof of workflow measurement.<b>Results:</b>Spectral results showed excellent agreement between measured and modelled spectra. Dose errors of < 2% were achieved for PDD curves. Full width at half maximum values for the 2D profiles were, on average, 0.95 mm higher in simulation compared to film. A star-shot test demonstrated the high geometrical accuracy of the system with a 0.3 mm diameter wobble circle. Finally, a mean absolute percent error of 5 ± 5% (1<i>σ</i>) was measured for the proof of workflow test.<b>Conclusions:</b>This initial characterization showcased the strengths and weaknesses of the KOALA system, with excellent isocenter precision and depth dose accuracy while lacking dosimetric accuracy in the 2D profiles. Further improvements on the source-to-collimator distance and treatment couch material can be made to improve the accuracy of a Monte Carlo model of the KOALA system.

Authors

Institutions

Publication Details

Journal
Biomedical Physics & Engineering Express
Published
2025-03-05
DOI
https://doi.org/10.1088/2057-1976/adbcb2
Citations
3
Primary Topic
Advanced Radiotherapy Techniques
Type
article
Field-Weighted Citation Impact
5.65

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Initial characterization of a novel dual-robot orthovoltage radiotherapy system

Magdalena Bazalova‐Carter, M Weil, J Atkinson, Sandhya Rottoo et al.
3 citations
Biomedical Physics & Engineering Express
Advanced Radiotherapy Techniques
5.65
article

Initial characterization of a novel dual-robot orthovoltage radiotherapy system

Magdalena Bazalova‐Carter, M Weil, J Atkinson, Sandhya Rottoo, Olivia Masella
article en
3 citations

Abstract

<b>Purpose:</b>Adequate access to radiotherapy is a critical global concern affecting low-resource settings such as low- and middle-income countries and rural regions. We propose to reduce this disparity by developing a novel low-cost radiotherapy device that treats using non-coplanar techniques and a 225 kVp x-ray tube.<b>Methods:</b>This novel device has been preliminarily characterized spectrally, via spectrometer measurements, dosimetrically, via percent depth dose curves and 2D profiles, and geometrically, via a coplanar star-shot. Dosimetric and geometric evaluations were then combined by performing a proof of workflow of the KOALA system. Monte Carlo simulations were run in TOPAS to validate dosimetric measurements and the proof of workflow measurement.<b>Results:</b>Spectral results showed excellent agreement between measured and modelled spectra. Dose errors of < 2% were achieved for PDD curves. Full width at half maximum values for the 2D profiles were, on average, 0.95 mm higher in simulation compared to film. A star-shot test demonstrated the high geometrical accuracy of the system with a 0.3 mm diameter wobble circle. Finally, a mean absolute percent error of 5 ± 5% (1<i>σ</i>) was measured for the proof of workflow test.<b>Conclusions:</b>This initial characterization showcased the strengths and weaknesses of the KOALA system, with excellent isocenter precision and depth dose accuracy while lacking dosimetric accuracy in the 2D profiles. Further improvements on the source-to-collimator distance and treatment couch material can be made to improve the accuracy of a Monte Carlo model of the KOALA system.

Biomedical Physics & Engineering ExpressVol. 11(2)
University of Victoria (CA), Ambient Micro (United States) (US), McGill University (CA)
Canada Research Chairs
No poverty
Openalex Percentile: Top 5%
Advanced Radiotherapy Techniques
5.65
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Initial characterization of a novel dual-robot orthovoltage radiotherapy system — Magdalena Bazalova‐Carter, M Weil, et al. · Biomedical Physics & Engineering Express (2025) | TGRS Research Map | TGRS