High-Adhesive Hydrogel-Based Strain Sensor in the Clinical Diagnosis of Anterior Talofibular Ligament Sprain
Anterior talofibular ligament (ATFL) sprain is one of the most prevalent sports-related injuries, so proper evaluation of ligament sprains is critical for treatment options. However, existing tests suffer from a lack of standardized quantitative evaluation criteria, interindividual variability, incompatible materials, or risks of infection. Although advanced medical diagnostic methods already have been using noninvasive, portable, and wearable diagnostic electronics, these devices have insufficient adhesion to accurately respond to internal body injuries. Therefore, we propose a high-adhesive hydrogel-based strain sensor made from gelatin, cellulose nanofiber (CNF), and cross-linked poly(acrylic acid) grafted with <i>N</i>-hydrosuccinimide ester. The adhesive strain sensor, with excellent conformability and stretchability, firmly adheres to the skin, making it suitable for accurately evaluating the severity of anterior talofibular ligament sprain. Its strong adhesive (up to 192 kPa) can adapt to the surface characterization of ankles. The high-adhesive hydrogel-based strain sensor has a high tensile strength (680%) and achieves a high gauge factor (GF) of 8.29. Simultaneously, it also presents a 40 μm ultralow detection limit. Additionally, after a deep learning model was integrated to improve sensing accuracy, the system achieved a diagnostic accuracy of 95%, significantly surpassing the magnetic resonance imaging (MRI) gold standard of 81.1%.
Authors
- Cheng Huang (ORCID: https://orcid.org/0000-0003-4371-7370)
- Bo Meng (ORCID: https://orcid.org/0000-0003-0457-7942)
- Xuanli Dong (ORCID: https://orcid.org/0009-0001-4652-8244)
- Cheng‐Yu Li (ORCID: https://orcid.org/0000-0002-9373-5625)
- Guanbo Min
- Xufeng Jiao (ORCID: https://orcid.org/0000-0002-2469-4030)
- Feng Qu (ORCID: https://orcid.org/0000-0003-0732-1109)
- Wei Yieng Tang (ORCID: https://orcid.org/0000-0002-9901-4933)
- Kun Xu (ORCID: https://orcid.org/0000-0002-2613-2402)
- Yusheng Li (ORCID: https://orcid.org/0000-0002-3404-0807)
- Weiguo Wang (ORCID: https://orcid.org/0000-0002-9050-440X)
- Jiaxuan Wu
- Tingyu Wang (ORCID: https://orcid.org/0000-0001-5000-7890)
- Wenjun Wang (ORCID: https://orcid.org/0000-0001-5644-1698)
Institutions
- Central South University (CN)
- Capital University (US)
- Shenzhen University (CN)
- Capital Medical University (CN)
- Chinese Academy of Sciences (CN)
- Chinese Academy of Medical Sciences & Peking Union Medical College (CN)
- China-Japan Friendship Hospital (CN)
- Peking Union Medical College Hospital (CN)
- National Clinical Research (US)
- Beijing Institute of Nanoenergy and Nanosystems (CN)
- Xiangya Hospital Central South University (CN)
- Beijing Chaoyang Emergency Medical Center (CN)
- University of Chinese Academy of Sciences (CN)
- Shandong Agricultural University (CN)
Publication Details
- Journal
- ACS Sensors
- Published
- 2025-03-05
- DOI
- https://doi.org/10.1021/acssensors.4c03472
- Primary Topic
- Advanced Sensor and Energy Harvesting Materials
- Type
- article
- Field-Weighted Citation Impact
- 0.00