Stereotactic radiotherapy for metastatic brain tumors: A comparative analysis of dose distributions among VMAT, Helical TomoTherapy, CyberKnife, Gamma Knife, and ZAP‐X

This study evaluates various radiotherapy techniques for treating metastatic brain tumor (BT), focusing on non-coplanar volumetric modulated arc radiotherapy (NC-VMAT), coplanar VMAT (C-VMAT), Helical TomoTherapy (HT), CyberKnife (CK), Gamma Knife (GK), and ZAP-X. CT images and structures of 12 patients who underwent CK for a single BT were utilized. Twelve treatment plans were created for each planning device. All plans adopted the approach of prescription doses to planning target volume D99.5%. They were divided into stereotactic radiosurgery (SRS) (prescription dose; 21-23 Gy) and stereotactic radiotherapy (SRT) (prescription dose; 30-36.5 Gy) groups and the same parameters evaluated included Gradient Index (GI), Paddick Conformity Index (CI), and treatment time (t-time). In the SRS group, mean values of GI and CI values were: NC-VMAT (4.28, 0.60), C-VMAT (5.61, 0.44), HT (4.68, 0.42), CK (4.31, 0.61), GK (2.81, 0.82), and ZAP-X (2.99, 0.80). In the SRT group: NC-VMAT (3.27, 0.84), C-VMAT (3.81, 0.82), HT (3.76, 0.65), CK (2.98, 0.77), GK (2.61, 0.90), and ZAP-X (2.80, 0.84). There were no significant differences in the mean values of CI and GI between ZAP-X and GK in both groups (p > 0.05). NC-VMAT and C-VMAT had shorter t-time than other techniques in both groups. ZAP-X is relatively superior in CI and GI for small tumors, similar to GK, while differences with NC-VMAT and CK diminish as tumor volume increases. ZAP-X, CK, and GK have longer t-time than other treatment techniques, regardless of volume.

Authors

Institutions

Publication Details

Journal
Journal of Applied Clinical Medical Physics
Published
2025-03-05
DOI
https://doi.org/10.1002/acm2.70046
Citations
5
Primary Topic
Advanced Radiotherapy Techniques
Type
article
Field-Weighted Citation Impact
9.41
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Stereotactic radiotherapy for metastatic brain tumors: A comparative analysis of dose distributions among VMAT, Helical TomoTherapy, CyberKnife, Gamma Knife, and ZAP‐X

Naoto Yanagisawa, Ryutaro Nomura, Zennosuke Mochizuki, Hikaru Nemoto et al.
5 citations
Journal of Applied Clinical Medical Physics
Advanced Radiotherapy Techniques
9.41
article

Stereotactic radiotherapy for metastatic brain tumors: A comparative analysis of dose distributions among VMAT, Helical TomoTherapy, CyberKnife, Gamma Knife, and ZAP‐X

Naoto Yanagisawa, Ryutaro Nomura, Zennosuke Mochizuki, Hikaru Nemoto, Hiroshi Ōnishi, Masahide Saito, Ryuma Sawada, Toshihiro Suzuki, Hiroshi Takahashi, Naoki Sano
article en
5 citations

Abstract

This study evaluates various radiotherapy techniques for treating metastatic brain tumor (BT), focusing on non-coplanar volumetric modulated arc radiotherapy (NC-VMAT), coplanar VMAT (C-VMAT), Helical TomoTherapy (HT), CyberKnife (CK), Gamma Knife (GK), and ZAP-X. CT images and structures of 12 patients who underwent CK for a single BT were utilized. Twelve treatment plans were created for each planning device. All plans adopted the approach of prescription doses to planning target volume D99.5%. They were divided into stereotactic radiosurgery (SRS) (prescription dose; 21-23 Gy) and stereotactic radiotherapy (SRT) (prescription dose; 30-36.5 Gy) groups and the same parameters evaluated included Gradient Index (GI), Paddick Conformity Index (CI), and treatment time (t-time). In the SRS group, mean values of GI and CI values were: NC-VMAT (4.28, 0.60), C-VMAT (5.61, 0.44), HT (4.68, 0.42), CK (4.31, 0.61), GK (2.81, 0.82), and ZAP-X (2.99, 0.80). In the SRT group: NC-VMAT (3.27, 0.84), C-VMAT (3.81, 0.82), HT (3.76, 0.65), CK (2.98, 0.77), GK (2.61, 0.90), and ZAP-X (2.80, 0.84). There were no significant differences in the mean values of CI and GI between ZAP-X and GK in both groups (p > 0.05). NC-VMAT and C-VMAT had shorter t-time than other techniques in both groups. ZAP-X is relatively superior in CI and GI for small tumors, similar to GK, while differences with NC-VMAT and CK diminish as tumor volume increases. ZAP-X, CK, and GK have longer t-time than other treatment techniques, regardless of volume.

Journal of Applied Clinical Medical PhysicsVol. 26(6)
Kasugai Municipal Hospital (JP), Aizawa Hospital (JP), University of Yamanashi (JP)
Good health and well-being
Openalex Percentile: Top 2%
Advanced Radiotherapy Techniques
9.41
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.