Design of a compacted-sized eye-tracking system with indexed gaze target for ring gantry linear accelerators: verification study using a motorized eye phantom

<i><b>Background</b></i>: Eye-tracking systems and gaze targets provide effective immobilization of the eye during ocular radiation therapy treatment. This study proposes a compact-sized eye-tracking system with a gaze target to provide a simple setup in a ring gantry LINAC. The device should have accurate repositioning, while the gaze target should be easily interchangeable.<i><b>Methods</b></i>: A compact-sized camera was mounted on a 3D-printed stand integrated with a gaze target. The gaze target can be fixed in different positions using an indexed-positioning system. The repositioning accuracy of this system was evaluated using Computed Tomography (CT) scans. The iris center position of the eye phantom was detected using fast radial symmetry transform. The iris center shift in the camera plane was converted to the 3D absolute displacement using the approximation of the spherical rotation of the eye globe. The tolerance of iris motion from gazing toward the gaze target in the camera plane can be estimated with prior knowledge of the iris center location when gazing toward the camera. The detection accuracy was evaluated on a motorized spherical eye phantom.<i><b>Results</b></i>: The mean repositioning errors of the camera and the gaze target were 0.18 mm (Range: 0.08-0.36 mm) and 0.31 mm (Range: 0.03-0.56 mm), respectively. For a typical distance of 200 mm from the camera to the tracked eye, the largest absolute error of iris center detection on a motorized spherical eye phantom was 0.08 mm, while the mean absolute error was less than the resolution of one pixel.<i><b>Conclusions</b></i>: This study proposed a compact-sized eye-tracking system with a gaze target with an easily reproducible setup. By converting the displacement of the motorized eye phantom iris center location in the camera plane to 3D coordinate displacement, accurate tolerance of the gaze direction of the eye can be achieved.

Authors

Institutions

Publication Details

Journal
Biomedical Physics & Engineering Express
Published
2025-03-05
DOI
https://doi.org/10.1088/2057-1976/adbcb0
Primary Topic
Gaze Tracking and Assistive Technology
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Design of a compacted-sized eye-tracking system with indexed gaze target for ring gantry linear accelerators: verification study using a motorized eye phantom

Louis K Y Lee, Albert Chow, Wilkey Wong, Queenie Tsung Kwan Shea
Biomedical Physics & Engineering Express
Gaze Tracking and Assistive Technology
article

Design of a compacted-sized eye-tracking system with indexed gaze target for ring gantry linear accelerators: verification study using a motorized eye phantom

Louis K Y Lee, Albert Chow, Wilkey Wong, Queenie Tsung Kwan Shea
article en

Abstract

<i><b>Background</b></i>: Eye-tracking systems and gaze targets provide effective immobilization of the eye during ocular radiation therapy treatment. This study proposes a compact-sized eye-tracking system with a gaze target to provide a simple setup in a ring gantry LINAC. The device should have accurate repositioning, while the gaze target should be easily interchangeable.<i><b>Methods</b></i>: A compact-sized camera was mounted on a 3D-printed stand integrated with a gaze target. The gaze target can be fixed in different positions using an indexed-positioning system. The repositioning accuracy of this system was evaluated using Computed Tomography (CT) scans. The iris center position of the eye phantom was detected using fast radial symmetry transform. The iris center shift in the camera plane was converted to the 3D absolute displacement using the approximation of the spherical rotation of the eye globe. The tolerance of iris motion from gazing toward the gaze target in the camera plane can be estimated with prior knowledge of the iris center location when gazing toward the camera. The detection accuracy was evaluated on a motorized spherical eye phantom.<i><b>Results</b></i>: The mean repositioning errors of the camera and the gaze target were 0.18 mm (Range: 0.08-0.36 mm) and 0.31 mm (Range: 0.03-0.56 mm), respectively. For a typical distance of 200 mm from the camera to the tracked eye, the largest absolute error of iris center detection on a motorized spherical eye phantom was 0.08 mm, while the mean absolute error was less than the resolution of one pixel.<i><b>Conclusions</b></i>: This study proposed a compact-sized eye-tracking system with a gaze target with an easily reproducible setup. By converting the displacement of the motorized eye phantom iris center location in the camera plane to 3D coordinate displacement, accurate tolerance of the gaze direction of the eye can be achieved.

Biomedical Physics & Engineering ExpressVol. 11(2)
Shanxi Medical University (CN), Cheung Kong Graduate School of Business (CN), CK Hutchison (China) (CN), University of Hong Kong (HK)
Good health and well-being
Openalex Percentile: Top 97%
Gaze Tracking and Assistive Technology
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.