Determination of glucose in exhaled breath and saliva by ion chromatography

A novel noninasive method was developed for determining glucose levels in human exhaled breath and saliva using ion chromatography. This innovative approach involves collecting exhaled breath and saliva samples using a self-designed condensation device and non-stimulative method to ensure minimal participant discomfort. The glucose contents in both exhaled breath condensate (EBC) and saliva were analyzed using ion chromatography, which is highly sensitive and specific. The experimental conditions were optimized, including a condensation temperature of -14 ℃ and an expiratory flow of 15 L/min. A Dionex CarboPac MA1 ion chromatography column (250 mm×4 mm) was used to separate glucose, with the column temperature maintained at 30 ℃. Sodium hydroxide solution (0.8 mol/L) with a pump flow rate of 0.4 mL/min was used as the mobile phase for ion chromatography. Under these conditions, glucose exhibited a good linear relationship in the range of 0.01-20 mg/L, with a correlation coefficient of 0.9999, along with limits of detection (LOD) and quantification (LOQ) of 2.1 and 7.0 μg/L, respectively. The intra- and inter-day precisions of glucose content in exhaled breath and saliva samples of ≤7.5% (<i>n</i>=5) and ≤8.4% (<i>n</i>=5), respectively. The results reveal that the glucose levels in exhaled breath and saliva are strongly correlated with blood glucose levels. The method was validated by measuring the glucose contents of exhaled breath and saliva from six diabetic patients and six healthy subjects. Little variation in the glucose contents of the exhaled breath of the two groups was observed under fasting states. However, the exhaled breath of the diabetic patients exhibited significantly higher (by factors of 6-80) glucose contents (48.4-140.0 ng/L) than those of healthy subjects (1.7-7.9 ng/L) 1 h after glucose ingestion. Saliva samples from fasting diabetic patients contained 1.2-5.0-times more glucose contents (87.6-158 mg/L) than those of healthy subjects (31.6-70.9 mg/L). In addition, the saliva of the diabetic patients exhibited glucose contents (136-257 mg/L) that were 1.8-7.7-times higher than those of the healthy subjects (33.1-75.2 mg/L) 2 h after glucose ingestion. The developed method provides a simple, precise, and non-invasive means of detecting glucose contents in a manner that does not harm the human body; hence, it is a promising non-invasive metabolic-monitoring tool. This study opens new avenues for the development of innovative technologies for monitoring glucose and other biomarkers, which is expected to greatly enhance metabolic-study accuracy and ease, particularly in the context of managing diabetes and other metabolic disorders.

Authors

Institutions

Publication Details

Journal
Chinese Journal of Chromatography
Published
2025-03-01
DOI
https://doi.org/10.3724/sp.j.1123.2024.06011
Primary Topic
Advanced Chemical Sensor Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Determination of glucose in exhaled breath and saliva by ion chromatography

Jianjun Xu, Yanqiu Zhu, Yue Zhuo, Chaoyan Lou
Chinese Journal of Chromatography
Advanced Chemical Sensor Technologies
article

Determination of glucose in exhaled breath and saliva by ion chromatography

Jianjun Xu, Yanqiu Zhu, Yue Zhuo, Chaoyan Lou
article en

Abstract

A novel noninasive method was developed for determining glucose levels in human exhaled breath and saliva using ion chromatography. This innovative approach involves collecting exhaled breath and saliva samples using a self-designed condensation device and non-stimulative method to ensure minimal participant discomfort. The glucose contents in both exhaled breath condensate (EBC) and saliva were analyzed using ion chromatography, which is highly sensitive and specific. The experimental conditions were optimized, including a condensation temperature of -14 ℃ and an expiratory flow of 15 L/min. A Dionex CarboPac MA1 ion chromatography column (250 mm×4 mm) was used to separate glucose, with the column temperature maintained at 30 ℃. Sodium hydroxide solution (0.8 mol/L) with a pump flow rate of 0.4 mL/min was used as the mobile phase for ion chromatography. Under these conditions, glucose exhibited a good linear relationship in the range of 0.01-20 mg/L, with a correlation coefficient of 0.9999, along with limits of detection (LOD) and quantification (LOQ) of 2.1 and 7.0 μg/L, respectively. The intra- and inter-day precisions of glucose content in exhaled breath and saliva samples of ≤7.5% (<i>n</i>=5) and ≤8.4% (<i>n</i>=5), respectively. The results reveal that the glucose levels in exhaled breath and saliva are strongly correlated with blood glucose levels. The method was validated by measuring the glucose contents of exhaled breath and saliva from six diabetic patients and six healthy subjects. Little variation in the glucose contents of the exhaled breath of the two groups was observed under fasting states. However, the exhaled breath of the diabetic patients exhibited significantly higher (by factors of 6-80) glucose contents (48.4-140.0 ng/L) than those of healthy subjects (1.7-7.9 ng/L) 1 h after glucose ingestion. Saliva samples from fasting diabetic patients contained 1.2-5.0-times more glucose contents (87.6-158 mg/L) than those of healthy subjects (31.6-70.9 mg/L). In addition, the saliva of the diabetic patients exhibited glucose contents (136-257 mg/L) that were 1.8-7.7-times higher than those of the healthy subjects (33.1-75.2 mg/L) 2 h after glucose ingestion. The developed method provides a simple, precise, and non-invasive means of detecting glucose contents in a manner that does not harm the human body; hence, it is a promising non-invasive metabolic-monitoring tool. This study opens new avenues for the development of innovative technologies for monitoring glucose and other biomarkers, which is expected to greatly enhance metabolic-study accuracy and ease, particularly in the context of managing diabetes and other metabolic disorders.

Chinese Journal of ChromatographyVol. 43(3)
Fujian Medical University (CN), Zhangzhou Municipal Hospital of Fujian Province (CN), China Jiliang University (CN), Zhejiang University of Technology (CN), Zhejiang University (CN)
Clean water and sanitation
Openalex Percentile: Top 96%
Advanced Chemical Sensor Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.