Full‐Field Assessment of Geometry and Collagenous Architecture of Porcine Valve Leaflets via Laser Micrometry and Quantitative Polarized Light Imaging

Despite the frequent failure of aortic valves and pediatric usage of pulmonary valves as a replacement, comparative studies on their full-field collagenous architecture and macroscale geometries are limited. We applied laser micrometry and quantitative polarized light imaging (QPLI), a novel technique for assessing collagen fiber organization, to porcine aortic (n = 8) and pulmonary (n = 8) valve leaflets to non-destructively compare thickness and anisotropy. We confirmed (1) light intensity and sample thickness are inversely related and (2) aortic valve leaflets are thicker with decreased fiber organization when unloaded. To demonstrate the ability of QPLI to capture dynamic collagen fiber alignment, we imaged leaflets during equibiaxial loading. There was an increase in the aortic leaflet's degree of alignment throughout loading, whereas the pulmonary valve leaflet exhibited relatively unchanged alignment. Ultimately, understanding the full-field organization of a leaflet's heterogeneous ECM and how it is altered by pathology can inform therapy development.

Authors

Institutions

Publication Details

Journal
Journal of Biophotonics
Published
2025-03-06
DOI
https://doi.org/10.1002/jbio.202400511
Citations
1
Primary Topic
Cardiac Valve Diseases and Treatments
Type
article
Field-Weighted Citation Impact
1.39

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Full‐Field Assessment of Geometry and Collagenous Architecture of Porcine Valve Leaflets via Laser Micrometry and Quantitative Polarized Light Imaging

S. Sreedhar, Colleen M. Witzenburg, Daniel Pearce
1 citations
Journal of Biophotonics
Cardiac Valve Diseases and Treatments
1.39
article

Full‐Field Assessment of Geometry and Collagenous Architecture of Porcine Valve Leaflets via Laser Micrometry and Quantitative Polarized Light Imaging

S. Sreedhar, Colleen M. Witzenburg, Daniel Pearce
article en
1 citations

Abstract

Despite the frequent failure of aortic valves and pediatric usage of pulmonary valves as a replacement, comparative studies on their full-field collagenous architecture and macroscale geometries are limited. We applied laser micrometry and quantitative polarized light imaging (QPLI), a novel technique for assessing collagen fiber organization, to porcine aortic (n = 8) and pulmonary (n = 8) valve leaflets to non-destructively compare thickness and anisotropy. We confirmed (1) light intensity and sample thickness are inversely related and (2) aortic valve leaflets are thicker with decreased fiber organization when unloaded. To demonstrate the ability of QPLI to capture dynamic collagen fiber alignment, we imaged leaflets during equibiaxial loading. There was an increase in the aortic leaflet's degree of alignment throughout loading, whereas the pulmonary valve leaflet exhibited relatively unchanged alignment. Ultimately, understanding the full-field organization of a leaflet's heterogeneous ECM and how it is altered by pathology can inform therapy development.

Journal of BiophotonicsVol. 18(6)
University of Wisconsin–Madison (US)
Division of Civil, Mechanical and Manufacturing Innovation
Openalex Percentile: Top 22%
Cardiac Valve Diseases and Treatments
1.39
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.