[Comparison of the accuracy between magnetic resonance hydrography and CT myelography in diagnosing of spontaneous intracranial hypotension syndrome].

<b>Objective:</b> To compare the accuracy of spinal magnetic resonance myelography (MRM) and CT myelography (CTM) in the detection of spontaneous intracranial hypotension (SIH). <b>Methods:</b> The clinica data of SIH patients at the Neurology Department of Zhongshan Hospital Affiliated to Fudan University between June 2021 and August 2023 were prospectively collected . MRM was performed first, CTM, followed by CTM. CTM results were used as the gold standard to verify the consistency of MRM and CTM examination, and the diagnostic results of epidural cerebrospinal fluid accumulation were observed. The abnormal accumulation of cerebrospinal fluid (CSF) was further recorded in 4 parts, namely, the posterior part of the cervical vertebra, the nerve root walking area, the side of the vertebra and the side of the ribs. Kappa consistency test was used to compare and analyze the evaluation results of the two examination methods. <b>Results:</b> A total of 31 patients were included in the study, including 13 males and 18 females, aged (40.7±7.0) years. The positive rate of CSF leakage detected by MRM was 93.5%(29 cases), and that detected by CTM was 87.1% (27 cases). Kappa consistency analysis showed that there was a high consistency between MRM and CTM (Kappa=0.635, <i>P</i><0.001). MRM had good consistency with CTM in detecting CSF accumulation along the nerve root area and paracostal area (Kappa values were 0.469 and 0.652, respectively). MRM had relatively low consistency with CTM in detecting CSF accumulation behind the C<sub>1-2</sub> vertebrae and in the paravertebral area (Kappa values were 0.241 and 0.271, respectively), but the former had a higher sensitivity (0.833, 95%<i>CI</i>:0.436-0.991), and the latter had a higher specificity (0.963, 95%<i>CI</i>:0.817-0.998). <b>Conclusions:</b> MRM has a comparable value to CTM in diagnosing epidural CSF accumulation in SIH patients, with good consistency. Besides, it is non-invasive and radiation-free, and may be a suitable alternative method for the initial assessment of SIH patients.

Authors

Institutions

Publication Details

Journal
PubMed
Published
2025-04-01
DOI
https://doi.org/10.3760/cma.j.cn112137-20241210-02796
Primary Topic
Neurosurgical Procedures and Complications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

[Comparison of the accuracy between magnetic resonance hydrography and CT myelography in diagnosing of spontaneous intracranial hypotension syndrome].

X Wang, Wanyue Xu, Y W Zhang, Jie‐Yi Lin et al.
1 links
PubMed
Neurosurgical Procedures and Complications
article

[Comparison of the accuracy between magnetic resonance hydrography and CT myelography in diagnosing of spontaneous intracranial hypotension syndrome].

X Wang, Wanyue Xu, Y W Zhang, Jie‐Yi Lin, Jian Ding
article en

Abstract

<b>Objective:</b> To compare the accuracy of spinal magnetic resonance myelography (MRM) and CT myelography (CTM) in the detection of spontaneous intracranial hypotension (SIH). <b>Methods:</b> The clinica data of SIH patients at the Neurology Department of Zhongshan Hospital Affiliated to Fudan University between June 2021 and August 2023 were prospectively collected . MRM was performed first, CTM, followed by CTM. CTM results were used as the gold standard to verify the consistency of MRM and CTM examination, and the diagnostic results of epidural cerebrospinal fluid accumulation were observed. The abnormal accumulation of cerebrospinal fluid (CSF) was further recorded in 4 parts, namely, the posterior part of the cervical vertebra, the nerve root walking area, the side of the vertebra and the side of the ribs. Kappa consistency test was used to compare and analyze the evaluation results of the two examination methods. <b>Results:</b> A total of 31 patients were included in the study, including 13 males and 18 females, aged (40.7±7.0) years. The positive rate of CSF leakage detected by MRM was 93.5%(29 cases), and that detected by CTM was 87.1% (27 cases). Kappa consistency analysis showed that there was a high consistency between MRM and CTM (Kappa=0.635, <i>P</i><0.001). MRM had good consistency with CTM in detecting CSF accumulation along the nerve root area and paracostal area (Kappa values were 0.469 and 0.652, respectively). MRM had relatively low consistency with CTM in detecting CSF accumulation behind the C<sub>1-2</sub> vertebrae and in the paravertebral area (Kappa values were 0.241 and 0.271, respectively), but the former had a higher sensitivity (0.833, 95%<i>CI</i>:0.436-0.991), and the latter had a higher specificity (0.963, 95%<i>CI</i>:0.817-0.998). <b>Conclusions:</b> MRM has a comparable value to CTM in diagnosing epidural CSF accumulation in SIH patients, with good consistency. Besides, it is non-invasive and radiation-free, and may be a suitable alternative method for the initial assessment of SIH patients.

PubMedVol. 105(13)
Sun Yat-sen University (CN), Fudan University (CN), Zhongshan Hospital (CN), The First Affiliated Hospital, Sun Yat-sen University (CN)
Openalex Percentile: Top 93%
Neurosurgical Procedures and Complications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.