Determination of trace anions in G2-grade phosphoric acid using two-dimensional ion-exclusion-ion-exchange chromatography with valve-switching technology

This study established a method for determining trace anions in G2-grade phosphoric acid under ultra-clean conditions that used two-dimensional ion-exclusion-ion-exchange chromatography coupled with valve-switching technology. The optimal flow rate of ultrapure water through the ion-exclusion column in the first dimension was determined to be 0.5 mL/min through comparative experiments. The valve-switching window was optimized to minimize enriching PO<sub>4</sub><sup>3-</sup> on the anion-enrichment column and reduce interference from the phosphoric-acid matrix. The use of external water mode for the suppressor led to lower baseline noise, and optimizing the elution program of the second dimension enabled target trace anions to be well separated, thereby avoiding the risk of a false positive for NO<sup>3-</sup>. The anions of Cl<sup>-</sup>, Br<sup>-</sup>, NO<sup>3-</sup>, and SO<sub>4</sub><sup>2-</sup> exhibited good linearities within the 0.5-20 μg/kg, with correlation coefficients ≥0.999. The limits of detection (LODs) and quantification (LOQs) were 0.09-0.29 μg/kg and 0.29-0.97 μg/kg, respectively. The spiked recoveries of each anion at four spiked levels ranged from 91.7% to 103.6%, with RSDs of 0.1%-4.9%. The developed method demonstrated excellent stability through repeated injections, and low detection limits; it is highly precise and accurate, and meets the detection requirements for trace anions in G2-grade phosphoric acid. Additionally, retention-time comparisons with single standard substances led to the discovery of other phosphorus-related anions and anion clusters, such as hypophosphite (HPO<sub>3</sub><sup>-</sup>) and hexametaphosphate (PO<sub>3</sub><sup>-</sup>)<sub>6</sub>, in G2-grade phosphoric acid, in addition to conventional anions. This finding is theoretically and practically significant for the future development of purification processes for higher-purity phosphoric acid.

Authors

Institutions

Publication Details

Journal
Chinese Journal of Chromatography
Published
2025-03-01
DOI
https://doi.org/10.3724/sp.j.1123.2024.04010
Primary Topic
Analytical Chemistry and Chromatography
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Determination of trace anions in G2-grade phosphoric acid using two-dimensional ion-exclusion-ion-exchange chromatography with valve-switching technology

Gao Tang, Yan Lü, Jiading Wang, Ye Tao et al.
Chinese Journal of Chromatography
Analytical Chemistry and Chromatography
article

Determination of trace anions in G2-grade phosphoric acid using two-dimensional ion-exclusion-ion-exchange chromatography with valve-switching technology

Gao Tang, Yan Lü, Jiading Wang, Ye Tao, H.-F. Lu
article en

Abstract

This study established a method for determining trace anions in G2-grade phosphoric acid under ultra-clean conditions that used two-dimensional ion-exclusion-ion-exchange chromatography coupled with valve-switching technology. The optimal flow rate of ultrapure water through the ion-exclusion column in the first dimension was determined to be 0.5 mL/min through comparative experiments. The valve-switching window was optimized to minimize enriching PO<sub>4</sub><sup>3-</sup> on the anion-enrichment column and reduce interference from the phosphoric-acid matrix. The use of external water mode for the suppressor led to lower baseline noise, and optimizing the elution program of the second dimension enabled target trace anions to be well separated, thereby avoiding the risk of a false positive for NO<sup>3-</sup>. The anions of Cl<sup>-</sup>, Br<sup>-</sup>, NO<sup>3-</sup>, and SO<sub>4</sub><sup>2-</sup> exhibited good linearities within the 0.5-20 μg/kg, with correlation coefficients ≥0.999. The limits of detection (LODs) and quantification (LOQs) were 0.09-0.29 μg/kg and 0.29-0.97 μg/kg, respectively. The spiked recoveries of each anion at four spiked levels ranged from 91.7% to 103.6%, with RSDs of 0.1%-4.9%. The developed method demonstrated excellent stability through repeated injections, and low detection limits; it is highly precise and accurate, and meets the detection requirements for trace anions in G2-grade phosphoric acid. Additionally, retention-time comparisons with single standard substances led to the discovery of other phosphorus-related anions and anion clusters, such as hypophosphite (HPO<sub>3</sub><sup>-</sup>) and hexametaphosphate (PO<sub>3</sub><sup>-</sup>)<sub>6</sub>, in G2-grade phosphoric acid, in addition to conventional anions. This finding is theoretically and practically significant for the future development of purification processes for higher-purity phosphoric acid.

Chinese Journal of ChromatographyVol. 43(3)
Zhejiang Medicine (China) (CN), China Jiliang University (CN)
Openalex Percentile: Top 96%
Analytical Chemistry and Chromatography
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.