Raman Gas Analyzer Based on a Multimode Diode Laser

The article presents the concept of gas analyzer based on Raman spectroscopy where a multimode blue diode laser is used as an excitation source. Methods for reducing the spectral width of the radiation of such a laser due to external feedback have been investigated. It has been shown that, when an optical scheme based on Fabry–Pero interferometer is used for this purpose, the resolution of the recorded Raman spectra can reach 8 cm–1. The performance of the developed Raman gas analyzer is presented and discussed. It was established that the achieved signal-to-noise ratio at the analysis time of 2 s allows detection of any type of molecule with concentration of >1%.

Authors

Institutions

Publication Details

Journal
Instruments and Experimental Techniques
Published
2024-12-01
DOI
https://doi.org/10.1134/s0020441224702038
Citations
1
Primary Topic
Spectroscopy and Laser Applications
Type
article
Field-Weighted Citation Impact
0.24
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Raman Gas Analyzer Based on a Multimode Diode Laser

V. K. Volkov, Д. В. Петров, I. I. Matrosov, M. A. Kostenko et al.
1 citations
Instruments and Experimental Techniques
Spectroscopy and Laser Applications
0.24
article

Raman Gas Analyzer Based on a Multimode Diode Laser

V. K. Volkov, Д. В. Петров, I. I. Matrosov, M. A. Kostenko, А. Р. Зарипов, Aleksandr S. Tanichev, S. D. Korkishko
article en
1 citations

Abstract

The article presents the concept of gas analyzer based on Raman spectroscopy where a multimode blue diode laser is used as an excitation source. Methods for reducing the spectral width of the radiation of such a laser due to external feedback have been investigated. It has been shown that, when an optical scheme based on Fabry–Pero interferometer is used for this purpose, the resolution of the recorded Raman spectra can reach 8 cm–1. The performance of the developed Raman gas analyzer is presented and discussed. It was established that the achieved signal-to-noise ratio at the analysis time of 2 s allows detection of any type of molecule with concentration of >1%.

Instruments and Experimental TechniquesVol. 67(6)
National Research Tomsk State University (RU), Institute of Monitoring of Climatic and Ecological Systems (RU)
Affordable and clean energy
Openalex Percentile: Top 46%
Spectroscopy and Laser Applications
0.24
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.